Mouse Monoclonal CD1C antibody - conjugated to PE. Suitable for Flow Cyt and reacts with Human samples.
View Alternative Names
CD1c, T-cell surface glycoprotein CD1c, CD1C
- Flow Cyt
Supplier Data
Flow Cytometry - PE Anti-CD1c antibody [L161] (AB326524)
Expression profiling on peripheral blood subsets using ab326524. Adaptive panel
HCDM CDMaps standardized procedures (Kuzilkova D et al. Front Immunol. 2022;13 : 827898) were used for cell isolation and surface staining of blood leukocytes, with the modification of staining protocol using cytometry test tubes.
Suspension of blood leukocytes isolated from buffy coats (2 x 10^6 cells) was added to the mixture of ab326524 (1 µg/ml in stained blood sample) and Monocyte Blocking Buffer, vortexed and incubated for 20 min. Next, optimized backbone antibody panel (HLDA Adaptive) was added to test tubes, vortexed and incubated for 20 min. The residual erythrocytes were lysed with 2 ml of 10X diluted EXCELLYSE Easy solution and incubated for 10 min. Finally, samples were centrifuged (670 g, 5 min.), supernatant removed and the cell pellet was resuspended in 200 µl of PBS for acquisition.
- Flow Cyt
Supplier Data
Flow Cytometry - PE Anti-CD1c antibody [L161] (AB326524)
Expression profiling on peripheral blood subsets using ab326524. Innate panel
HCDM CDMaps standardized procedures (Kuzilkova D et al. Front Immunol. 2022;13 : 827898) were used for cell isolation and surface staining of blood leukocytes, with the modification of staining protocol using cytometry test tubes.
Suspension of blood leukocytes isolated from buffy coats (2 x 10^6 cells) was added to the mixture of ab326524 (1 µg/ml in stained blood sample) and Monocyte Blocking Buffer, vortexed and incubated for 20 min. Next, optimized backbone antibody panel (HLDA Innate) was added to test tubes, vortexed and incubated for 20 min. The residual erythrocytes were lysed with 2 ml of 10X diluted EXCELLYSE Easy solution and incubated for 10 min. Finally, samples were centrifuged (670 g, 5 min.), supernatant removed and the cell pellet was resuspended in 200 µl of PBS for acquisition.
- Flow Cyt
Supplier Data
Flow Cytometry - PE Anti-CD1c antibody [L161] (AB326524)
Analysis of the antibody staining profile was performed on blood leukocytes isolated from buffy coats. HCDM CDMaps standardized procedures (Kuzilkova D et al. Front Immunol. 2022;13 : 827898) were used for cell isolation and surface staining of blood leukocytes, with the modification of staining protocol using cytometry test tubes.
ab326524 was used in concentration 1 µg/ml in stained blood sample (2 x 10^6 cells).
Related conjugates and formulations (4)
-
Anti-CD1c antibody [L161]
-
660 APC
APC Anti-CD1c antibody [L161]
-
387 mFluor™ UV375
mFluor™ UV375 Anti-CD1c antibody [L161]
-
mFluor™ Violet 450 Anti-CD1c antibody [L161]
Reactivity data
Properties and storage information
Form
Purification technique
Purification notes
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com