Rabbit Recombinant Monoclonal UBE3A antibody. Carrier free. Suitable for sELISA and reacts with Human samples.
pH: 7.2 - 7.4
Constituents: 100% PBS
sELISA | |
---|---|
Human | Tested |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info - | Notes - |
E3 ubiquitin-protein ligase which accepts ubiquitin from an E2 ubiquitin-conjugating enzyme in the form of a thioester and transfers it to its substrates (PubMed:10373495, PubMed:16772533, PubMed:19204938, PubMed:19233847, PubMed:19325566, PubMed:19591933, PubMed:22645313, PubMed:24273172, PubMed:24728990, PubMed:30020076). Several substrates have been identified including the BMAL1, ARC, LAMTOR1, RAD23A and RAD23B, MCM7 (which is involved in DNA replication), annexin A1, the PML tumor suppressor, and the cell cycle regulator CDKN1B (PubMed:10373495, PubMed:19204938, PubMed:19325566, PubMed:19591933, PubMed:22645313, PubMed:24728990, PubMed:30020076). Additionally, may function as a cellular quality control ubiquitin ligase by helping the degradation of the cytoplasmic misfolded proteins (PubMed:19233847). Finally, UBE3A also promotes its own degradation in vivo. Plays an important role in the regulation of the circadian clock: involved in the ubiquitination of the core clock component BMAL1, leading to its proteasomal degradation (PubMed:24728990). Acts as transcriptional coactivator of progesterone receptor PGR upon progesterone hormone activation (PubMed:16772533). Acts as a regulator of synaptic development by mediating ubiquitination and degradation of ARC (By similarity). Required for synaptic remodeling in neurons by mediating ubiquitination and degradation of LAMTOR1, thereby limiting mTORC1 signaling and activity-dependent synaptic remodeling (By similarity). Synergizes with WBP2 in enhancing PGR activity (PubMed:16772533). (Microbial infection) Catalyzes the high-risk human papilloma virus E6-mediated ubiquitination of p53/TP53, contributing to the neoplastic progression of cells infected by these viruses.
E6AP, EPVE6AP, HPVE6A, UBE3A, Ubiquitin-protein ligase E3A, E6AP ubiquitin-protein ligase, HECT-type ubiquitin transferase E3A, Human papillomavirus E6-associated protein, Oncogenic protein-associated protein E6-AP, Renal carcinoma antigen NY-REN-54
Rabbit Recombinant Monoclonal UBE3A antibody. Carrier free. Suitable for sELISA and reacts with Human samples.
pH: 7.2 - 7.4
Constituents: 100% PBS
ab323672 is a BSA and Azide Free antibody supplied in an unconjugated format and it is suitable for sandwich ELISAs to quantify Human UBE3A. The recommended pair for sandwich ELISA is:
Capture: Anti-UBE3A antibody [EPR26740-16] - BSA and Azide free Capture ab323671, Human UBE3A Capture Antibody (unconjugated)
Detector: ab323672, Human UBE3A Detector Antibody (unconjugated)
The reference range value is 19.5-1250 pg/mL.
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
This product is a recombinant monoclonal antibody, which offers several advantages including:
For more information, read more on recombinant antibodies.
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.
This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Please note that the range provided for this antibody is only an estimation based on the performance of the product using the recommended antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody in your assay.
We have tested this species and application combination and it works. It is covered by our product promise.
We have not tested this specific species and application combination in-house, but expect it will work. It is covered by our product promise.
This species and application combination has not been tested, but we predict it will work based on strong homology. However, this combination is not covered by our product promise.
We do not recommend this combination. It is not covered by our product promise.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Interpolated concentration of UBE3A was measured in duplicate at different sample concentrations. Undiluted samples are as follows: HeLa cell extract 31.25 ug/ml and HEK-293 cell extract 31.25 ug/ml. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- standard deviation, n=2). Sample dilutions are made in 1% Bovine Serum Albumin (BSA). Data represented here are indicative of assay working using example of biological samples. However, we do not guarantee same sensitivity level due to biological variation.
Sandwich ELISA using human UBE3A immunogen protein standard curve with the capture antibody Anti-UBE3A antibody [EPR26740-16] - BSA and Azide free Capture ab323671 at 2 ug/mL and detector antibody ab323672 at 0.5 ug/mL. Background-subtracted absorbance data values (mean +/- standard deviation) are displayed.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com