Skip to main content

Rabbit Recombinant Monoclonal uPA Receptor/U-PAR antibody. Carrier free. Suitable for WB, IHC-P and reacts with Human samples.

Be the first to review this product! Submit a review

Images

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (AB251557), expandable thumbnail
  • Western blot - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (AB251557), expandable thumbnail
  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (AB251557), expandable thumbnail
  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (AB251557), expandable thumbnail
  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (AB251557), expandable thumbnail

Key facts

Isotype
IgG
Host species
Rabbit
Storage buffer

pH: 7.2 - 7.4
Constituents: PBS

Form
Liquid
Clonality
Monoclonal

Immunogen

  • The exact immunogen used to generate this antibody is proprietary information.

Reactivity data

Select an application
Product promiseTestedExpectedPredictedNot recommended
WBIHC-P
Human
Tested
Tested

Tested
Tested

Species
Human
Dilution info
-
Notes

Perform heat-mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

Tested
Tested

Species
Human
Dilution info
-
Notes

Perform heat-mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

Associated Products

Select an associated product type

2 products for Alternative Product

Target data

Function

Acts as a receptor for urokinase plasminogen activator (PubMed:15677461). Plays a role in localizing and promoting plasmin formation. Mediates the proteolysis-independent signal transduction activation effects of U-PA. It is subject to negative-feedback regulation by U-PA which cleaves it into an inactive form.

Alternative names

Recommended products

Rabbit Recombinant Monoclonal uPA Receptor/U-PAR antibody. Carrier free. Suitable for WB, IHC-P and reacts with Human samples.

Key facts

Isotype
IgG
Form
Liquid
Clonality
Monoclonal
Immunogen
  • The exact immunogen used to generate this antibody is proprietary information.
Carrier free
Yes
Clone number
EPR20191
Purification technique
Affinity purification Protein A
Concentration
Loading...

Storage

Shipped at conditions
Blue Ice
Appropriate short-term storage conditions
+4°C
Appropriate long-term storage conditions
+4°C
Storage information
Do Not Freeze

Notes

ab251557 is the carrier-free version of Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106.

Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.

This product is a recombinant monoclonal antibody, which offers several advantages including:

  • - High batch-to-batch consistency and reproducibility
  • - Improved sensitivity and specificity
  • - Long-term security of supply
  • - Animal-free batch production

For more information, read more on recombinant antibodies.

Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.

This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.

Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.

This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.

Product promise

We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.

In the unlikely event of one of our products not working as expected, you are covered by our product promise.

Full details and terms and conditions can be found here:
Terms & Conditions.

5 product images

  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557), expandable thumbnail

    Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557)

    This data was developed using Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106, the same antibody clone in a different buffer formulation.Immunohistochemical analysis of paraffin-embedded human ovarian cancer tissue labeling uPA Receptor/U-PAR with Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Membranous staining on dissociative cancer cells in blood vessel of human ovarian cancer is observed [PMID: 25120753]. Counter stained with Hematoxylin. Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

  • Western blot - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557), expandable thumbnail

    Western blot - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557)

    This data was developed using Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106, the same antibody clone in a different buffer formulation.

    Blocking and dilution buffer: 5% NFDM/TBST.

    PMA-stimulated U937 cells express uPA Receptor/U-PAR in the range of 35kDa-60kDa. Non-stimulated U937 cells are negative. The deglycosylated form of the protein is at 35 kDa and the highly glycosylated protein is at 60kDa (PMID: 24999729).

    All lanes: Western blot - Anti-uPA Receptor/U-PAR antibody [EPR20191] (Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106) at 1/1000 dilution

    Lane 1: Untreated U937 (Human histiocytic lymphoma cell line) whole cell lysate at 10 µg

    Lane 2: U937 whole cell lysate treated with 200nM PMA (Phorbol-12-myristate-13-acetate) for 72 hours at 10 µg

    Secondary

    All lanes: Western blot - Goat Anti-Rabbit IgG H&L (HRP) (Goat Anti-Rabbit IgG H&L (HRP) ab97051) at 1/100000 dilution

    Predicted band size: 37 kDa

    Observed band size: 35-65 kDa

    Exposure time: 15s

  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557), expandable thumbnail

    Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557)

    This data was developed using Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106, the same antibody clone in a different buffer formulation.Immunohistochemical analysis of paraffin-embedded human ovarian cancer tissue labeling uPA Receptor/U-PAR with Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Membranous staining on the macrophages of human ovarian cancer is observed [PMID: 25575713]. Counter stained with Hematoxylin. Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557), expandable thumbnail

    Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557)

    This data was developed using Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106, the same antibody clone in a different buffer formulation.Immunohistochemical analysis of paraffin-embedded human lung cancer tissue labeling uPA Receptor/U-PAR with Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Cytoplasmic staining on the stromal cells of human lung cancer is observed [PMID: 25575713]. Counter stained with Hematoxylin. Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557), expandable thumbnail

    Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-uPA Receptor/U-PAR antibody [EPR20191] - BSA and Azide free (ab251557)

    This data was developed using Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106, the same antibody clone in a different buffer formulation.Immunohistochemical analysis of paraffin-embedded human artery tissue labeling uPA Receptor/U-PAR with Anti-uPA Receptor/U-PAR antibody [EPR20191] ab218106 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Positive staining on the neutrophils in human artery is observed [PMID: 25575713]. Counter stained with Hematoxylin. Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.

Downloads

Product protocols

For this product, it's our understanding that no specific protocols are required. You can:

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com