The 10kD Spin Columns (ab93349) are disposable ultrafiltration devices for the concentration or deproteinization of biological samples.


Images

Other - 10kD Spin Column (AB93349), expandable thumbnail

Publications

  • JCI insight :2021
    The pentose phosphate pathway mediates hyperoxia-induced lung vascular dysgenesis and alveolar simplification in neonates.
    Applications:
    Unspecified application
    Reactive species:
    Unspecified reactive species
    Jiannan Gong et. al.
    PubMed 33497360
  • Frontiers in medicine 7:5810822020
    Anesthesia-Sepsis-Associated Alterations in Liver Gene Expression Profiles and Mitochondrial Oxidative Phosphorylation Complexes.
    Applications:
    Unspecified application
    Reactive species:
    Unspecified reactive species
    Hari Prasad Osuru et. al.
    PubMed 33392215

Reactivity data

Application

Purification

Reactivity

Reacts

Dilution info

-

Notes

-

What's included?

25 Unit
Components
Concentrator cup: Polycarbonate
25 x 1 Unit
Filtrate vessel: Polypropylene
25 x 1 Unit
Membrane: 10,000 MWCO Polyethersulfone
25 x 1 Unit

Recommended products

  1. Loading...
  2. Loading...
  3. Loading...
  4. Loading...

The 10kD Spin Columns (ab93349) are disposable ultrafiltration devices for the concentration or deproteinization of biological samples.

Storage

Shipped at conditions

Ambient - Can Ship with Ice

Appropriate short-term storage conditions

Ambient

Appropriate long-term storage conditions

Ambient

Storage information

Ambient

Notes

The 10kD Spin Columns (ab93349) are disposable ultrafiltration devices for the concentration or deproteinization of biological samples.

They can be used in either a swing bucket or fixed angle rotors which accept 2.0 mL centrifuge tube at maximum speed 10000 x g (5-10 mins). The vertical membrane design and thin channel filtration chamber minimizes membrane fouling and provides high speed concentration, even laden solutions. It is specifically designed with low internal surface and membrane area in order to achieve superior recovery from dilute solution.

Maximum initial sample volume is 500μL. The dead stop volume is approximately 20-25μL.

If working with cell or tissue lysates, we generally recommend the TCA Sample Deproteinization Kit or using a PCA/KOH Deproteinization protocol. If it is critical to use a spin column with a cell or tissue lysate then, to avoid blocking the filter, first centrifuge the lysate samples at ~14,000 rpm for 10-20 mins to pellet debris, and then use the resulting supernatant with the spin column.

Product promise

We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.

In the unlikely event of one of our products not working as expected, you are covered by our product promise.

Full details and terms and conditions can be found here:
Terms & Conditions.

1 product image

  • Other - 10kD Spin Column (ab93349), expandable thumbnail

    Other - 10kD Spin Column (ab93349)

    Representative 10kD Spin Column (ab93349).

Downloads

Product protocols

For this product, it's our understanding that no specific protocols are required. You can:

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com