Suitable for ICC, WB, IHC-P, ELISA. Cited in 28 publications.
Application | Reactivity | Dilution info | Notes |
---|---|---|---|
Application ICC | Reactivity Reacts | Dilution info - | Notes - |
Application WB | Reactivity Reacts | Dilution info 1/5000 - 1/50000 | Notes (Chemiluminescent) |
Application IHC-P | Reactivity Reacts | Dilution info 1/100 - 1/1000 | Notes - |
Application ELISA | Reactivity Reacts | Dilution info 1/5000 - 1/50000 | Notes (Primary ELISA) |
Select an associated product type
Igh-4, Ighg1, Ig gamma-1 chain C region secreted form
Suitable for ICC, WB, IHC-P, ELISA. Cited in 28 publications.
By immunoelectrophoresis and ELISA this antibody reacts specifically with Mouse IgG and with light chains common to other Mouse immunoglobulins. No antibody was detected against non immunoglobulin serum proteins.
pH: 6.8 - 7.4
Preservative: 0.09% Sodium azide
Constituents: 1.19% HEPES, 0.58% Sodium chloride, 0.2% BSA, 0.0095% Magnesium chloride, 0.00136% Zinc chloride
This antibody was isolated by affinity chromatography using antigen coupled to agarose beads and conjugated to Alkaline Phosphatase (AP).
Part of the AbExcel range.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
All lanes: Western blot - Anti-beta Actin antibody [mAbcam 8226] - Loading Control (Anti-beta Actin antibody [mAbcam 8226] - Loading Control ab8226) at 1 µg/mL
All lanes: HeLa (Human epithelial carcinoma cell line) Whole Cell Lysate at 10 µg
Lanes 1 - 2: Western blot - Goat Anti-Mouse IgG H&L (Alkaline Phosphatase) (ab97020) at 1/5000 dilution
Lanes 3 - 4: Western blot - Goat Anti-Mouse IgG H&L (Alkaline Phosphatase) (ab97020) at 1/20000 dilution
Lanes 5 - 6: Western blot - Goat Anti-Mouse IgG H&L (Alkaline Phosphatase) (ab97020) at 1/50000 dilution
Developed using the ECL technique.
Performed under reducing conditions.
Predicted band size: 36 kDa
Exposure time: 4min
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.