For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Customized Products & Partnerships
    Customized Products & Partnerships

    Customized products and commercial partnerships to accelerate your diagnostic and therapeutic programs.

    Customized products

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

Explore the power of knock-out cell lines for your research

  1. Link

    fade-fluorescencemounting-medium-aqueous-fluoroshield-ab104135.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Kits/ Lysates/ Other Tools and Reagents IHC Tools/ Reagents
Share by email

Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)

  • Datasheet
  • SDS
Reviews (1)Q&A (3)References (30)

Product price, shipping and contact information

Currently unavailable

Sorry, we can't display this right now.

Please contact us to place your order, or try again later.

 

Loading size & price…

 

Shipping and order information

Shipping info

Promotion Information

Abpromise

Guaranteed product quality, expert customer support.

Find out more.

Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)
  • Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)
  • Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)

You may also be interested in

Mounting
Product image
Mounting Medium With DAPI - Aqueous, Fluoroshield (ab104139)
Secondary
Product image
Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) (ab150077)
Primary
Product image
Anti-LKB1 antibody [EPR19379] (ab199970)

View more associated products

Overview

  • Product name

    Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield
    See all Fluoroshield reagents
  • General notes

    Anti-Fade Fluorescence Mounting Medium ab104135 (previously called Fluoroshield Mounting Medium) is an aqueous mounting medium designed to preserve fluorescence when imaging tissues and cell samples.

    The formulation prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluor® 488, Alexa Fluor® 594, Green fluorescent protein (GFP), tetramethyl rhodamine, R-Phycoerythrin (R-PE), Phycocyanin (PC), and Allophycocyanin (APC).

    Fluorescence is retained during prolonged storage at 4°C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes, R-PE, PC and APC.

    Mounting media products

    For fluorescent cell and tissue staining, Abcam recommends this product (Fluorescence Mounting Medium ab104135), Mounting Medium with DAPI ab104139, and Mounting Medium with PI ab104129. For thick sections or tissues containing lots of fat, we recommend Glycerol Mounting Medium with DAPI ab188804.

    For chromogenic immunohistochemistry, such as with DAB, AEC, or Fast Red, we recommend aqueous Mounting Medium ab64230, or organic Limonene Mounting Medium ab104141. 


    Procedure

    - Bring the vial to room temperature.

    - Rinse slide to be mounted with distilled or deionized, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface.

    - Turn the vial upside down and open the dropper to remove any air bubbles.

    - Apply 3-4 drops of mounting medium directly on top of the specimen and spread out evenly by tilting slide back and forth or spread evenly with a 0.2 ml plastic pipette tip making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide against paper towel.

    - Let stand at room temperature for about 5 minutes.

    - Apply cover slip carefully avoiding air bubbles.

    - The specimen is ready for visualization under a microscope.

    Seal the edges of cover slip with nail polish, any organic medium or Limonene mounting medium ab104141. If a coverslip is not sealed, air bubbles will appear in a few days.

    Store the slide in the dark at 2-8°C.

    Removal of Coverslip Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deiononized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

Properties

  • Form

    Liquid
  • Storage instructions

    Store at +4°C. Do Not Freeze. Store In the Dark.
  • Storage buffer

    Preservative: 0.05% Sodium azide
    Constituent: 84% Water
  • Concentration information loading...
  • Research areas

    • Kits/ Lysates/ Other
    • Tools and Reagents
    • IHC Tools/ Reagents
    • Kits/ Lysates/ Other
    • Kits
    • IHC Kits
    • Kits/ Lysates/ Other
    • Kits
    • IHC tools
    • Mounting Medium

Images

  • Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)
    Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)Image from Guan-Yu et al., PLoS One, 9(9):e106538; doi: 10.1371/journal.pone.0106538. Reproduced under the Creative Commons license https://creativecommons.org/licenses
    Guan-Yu Xiao ,I-Hsuan Liu ,Chun-Chun Cheng,Chia-Chun Chang,Yen-Hua Lee,Winston Teng-Kuei Cheng,Shinn-Chih Wu
    Published: September 8, 2014https://doi.org/10.1371/journal.pone.0106538
  • Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)
    Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)Image from Hurley et al., PLoS One, 11(9):e0163531; doi: 10.1371/journal.pone.0163531. Reproduced under the Creative Commons license https://creativecommons.org/licenses/
    Hurley SM, Lutay N, Holmqvist B, Shannon O (2016) The Dynamics of Platelet Activation during the Progression of Streptococcal Sepsis. PLoS ONE 11(9): e0163531. https://doi.org/10.1371/journal.pone.0163531
  • Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)
    Immunohistochemistry (PFA perfusion fixed frozen sections) - Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield (ab104135)Image from Hurley et al., PLoS One, 11(9):e0163531; doi: 10.1371/journal.pone.0163531. Reproduced under the Creative Commons license https://creativecommons.org/licenses

    Dioli C, Patrício P, Sousa N, et al. Chronic stress triggers divergent dendritic alterations in immature neurons of the adult hippocampus, depending on their ultimate terminal fields. Transl Psychiatry. 2019;9(1):143. Published 2019 Apr 26. doi:10.1038/s41398-019-0477-7

Protocols

To our knowledge, customised protocols are not required for this product. Please try the standard protocols listed below and let us know how you get on.

Click here to view the general protocols

Datasheets and documents

  • SDS download

  • Datasheet download

    Download

References (30)

Publishing research using ab104135? Please let us know so that we can cite the reference in this datasheet.

ab104135 has been referenced in 30 publications.

  • Shakova FM  et al. Protective Effects of PGC-1a Activators on Ischemic Stroke in a Rat Model of Photochemically Induced Thrombosis. Brain Sci 11:N/A (2021). PubMed: 33806692
  • Liu J  et al. Rapamycin Preserves Neural Tissue, Promotes Schwann Cell Myelination and Reduces Glial Scar Formation After Hemi-Contusion Spinal Cord Injury in Mice. Front Mol Neurosci 13:574041 (2020). PubMed: 33551740
  • Cao S  et al. Fast Localization and Sectioning of Mouse Locus Coeruleus. Biomed Res Int 2020:4860735 (2020). PubMed: 32190666
  • Zhao Y  et al. Improving immunogenicity and safety of flagellin as vaccine carrier by high-density display on virus-like particle surface. Biomaterials 249:120030 (2020). PubMed: 32315864
  • Ferreiro E  et al. Chronic hyperglycemia impairs hippocampal neurogenesis and memory in an Alzheimer's disease mouse model. Neurobiol Aging 92:98-113 (2020). PubMed: 32417750
View all Publications for this product

Customer reviews and Q&As

Show All Reviews Q&A
Submit a question

1-3 of 3 Q&A

Question

Dear Sirs,



What is the exp date for the product ab104135



Many thanks in advance,

Read More

Abcam community

Verified customer

Asked on May 07 2013

Answer



We do not have specific use by dates for most our products. If stored correctly, the products remain suitable for use for months and even for years.

However, we do strongly suggest to store the products as recommended on their respective datasheet and if no other information is given the product is stable for at least one year from teh date of purchase.

I can confirm that ab104135 (Fluoroshield Mounting Medium (20ml)) is stable and covered by our guarantee when stored at +4°C in the dark for one year.

https://www.abcam.com/abpromise

Read More

Abcam Scientific Support

Answered on May 07 2013

Question


Inquiry: Hi, Can you give me the refractive index of Fluoroshield Mounting Media with DAPI? thanks!

Read More

Abcam community

Verified customer

Asked on May 15 2012

Answer

Thank you for contacting Abcam.

For ab104135 the refractive index is 1.364 ± 0.002.

If there is anything else I can help you with, please let me know.

Read More

Abcam Scientific Support

Answered on May 15 2012

Question

What is the refractive index of Fluoroshield mounting medium?

Read More

Abcam community

Verified customer

Asked on Aug 30 2011

Answer

Thank you for your inquiry. The refractive index of Fluoroshield Mounting Medium is: 1.364 ± 0.002 Please note that these numbers apply to these mounting mediums in solution. Refractive indexes change when the water solvent evaporates and mounting media dries on slides. We do not have the means to measure the refractive indexes of dry mounting mediums; however we expect the numbers to go higher when dried. The refractive index of water is 1.3330. If you are using other Fluoroshield Mounting Media (e.g. with DAPI), we also have the refractive index available on request. I hope this information is helpful to you. Please do not hesitate to contact us if you need any further advice or information.

Read More

Abcam Scientific Support

Answered on Aug 30 2011

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Get resources and offers direct to your inbox Sign up
A-Z by research area
  • Cancer
  • Cardiovascular
  • Cell biology
  • Developmental biology
  • Epigenetics & Nuclear signaling
  • Immunology
  • Metabolism
  • Microbiology
  • Neuroscience
  • Signal transduction
  • Stem cells
A-Z by product type
  • Primary antibodies
  • Secondary antibodies
  • Biochemicals
  • Isotype controls
  • Flow cytometry multi-color selector
  • Kits
  • Loading controls
  • Lysates
  • Peptides
  • Proteins
  • Slides
  • Tags and cell markers
  • Tools & Reagents
Help & support
  • Support
  • Make an Inquiry
  • Protocols & troubleshooting
  • Placing an order
  • RabMAb products
  • Biochemical product FAQs
  • Training
  • Browse by Target
Company
  • Corporate site
  • Investor relations
  • Company news
  • Careers
  • About us
  • Blog
Events
  • Tradeshows
  • Conferences
International websites
  • abcam.cn
  • abcam.co.jp

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
  • Modern slavery statement
© 1998-2022 Abcam plc. All rights reserved.