Overview

  • Product name

    Goat Anti-Mouse IgG H&L (Chromeo™ 642)
    See all IgG secondary antibodies
  • Host species

    Goat
  • Target species

    Mouse
  • Specificity

    ab60318 reacts with whole molecular mouse IgG and the light chains of other mouse immunoglobulins. No cross-reactivity with non-immunoglobulin serum proteins observed.
  • Tested applications

    Suitable for: ICC/IFmore details
  • Immunogen

    Mouse IgG.

  • Conjugation

    Chromeo™ 642

Properties

  • Form

    Liquid
  • Storage instructions

    Shipped at 4°C. Store at +4°C.
  • Storage buffer

    pH: 7.40
    Preservative: 0.013% Sodium azide
    Constituents: 0.42% Potassium phosphate, 0.87% Sodium chloride
  • Concentration information loading...
  • Purity

    Immunogen affinity purified
  • Conjugation notes

    Chromeo™ 642 is spectrally similar to Cy5®. Conjugated antibodies exhibit superior luminescent properties and stability towards photobleaching, and have absorption and emission maxima of approximately 642 and 666 nm which are compatible with common excitation sources and filter sets. Molar extinction Coefficient: 180,000 M-1cm-1 (measured at Amax) Quantum Yield: ~ 7 % Excitation Wavelength Range: 630 to 655 nm Emission Wavelength Range: 650 to 670 nm
  • Clonality

    Polyclonal
  • Isotype

    IgG
  • Research areas

Applications

Our Abpromise guarantee covers the use of ab60318 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
ICC/IF
  • Application notes
    ICC/IF: 1/1000 - 1/2000.
    Plate-based assays: 1/800 to 1/1000.


    Not yet tested in other applications.
    Optimal dilutions/concentrations should be determined by the end user.
  • Images

    • ab60318 staining a mouse monoclonal antibody to alpha Tubulin in HeLa cells by Immunocytochemistry/Immunofluorescense with a DAPI nuclear counterstain.

    References

    ab60318 has not yet been referenced specifically in any publications.

    Customer reviews and Q&As

    1-4 of 4 Abreviews or Q&A

    Answer

    Thank you for confirming these details and for your cooperation. The details provided enable us to closely monitor the quality of our products.

    I am sorry these secondary antibodies did not perform as stated on the datasheet and for the inconvenience this has caused. As requested, I have issued a free of charge replacements with the order number #####.

    To check the status of the order please contact our Customer Service team and reference this number.

    Please note that these free of charge replacement vials are also covered by our Abpromise guarantee. Should you still be experiencing difficulties, or if you have any further questions, please do not hesitate to let us know.

    I wish you the best of luck with your research.

    Read More

    Question
    Answer

    Thank you for taking the time to complete our questionnaire. The details you have kindly provided will provide us with vital information for our monitoring of product quality

    I appreciate the time you have spent in the laboratory and understand your concerns. It is regrettable the results have not been succesful from these two secondaries. Reviewing the details, I am sorry there are no further tips to provide on this occasion to help improve the results. I can suggest you have regrettably recieved a bad vial.

    I apologise for the inconvenience and am pleased to offer you a free of charge replacement or credit note in compensation.

    For our records, and as a consideration to confirm the source of the problem, I would also appreciate if you could let me know if these antibodies have been tried with different primary antibodies? What were the results?

    Thank you for your cooperation. I look forward to hearing from you with details of how you would like to proceed.

    Read More

    Answer

    Thank you for taking the time to contact us. I am sorry to hear you have had difficulty obtaining satisfactory results from these two secondary antibodies.

    I appreciate the time you have spent in the laboratory and understand your concerns. It is regrettable the results have not been succesful.

    I would like to reassure you that these antibodies are both tested and covered by our guarantee for ICC-IF. Before deciding how to proceed, I would like to investigate this particular case further for you, and also obtain some further information for our quality records.

    In order to do this, I have enclosed a questionnaire below. I would appreciate if you could complete this. It will help you put the information we require together very easily.

    In the event that a product is not functioning in the tested applications and species cited on the product data sheet (and the problem has been reported within 6 months of purchase), we will be pleased to provide a credit note, free of charge replacement or refund.

    Thank you for your time and cooperation. We look forward to receiving the completed questionaire.



    Order Details
    Antibody code:


    Lot number:

    Purchase order number
    or preferably Abcam order number:


    General Information
    Antibody storage conditions (temperature/reconstitution etc)


    Description of the problem (high background, low signal, non-specific satining etc.)

    Sample (Species/Tissue/Cell Type/Cell Line etc.)


    Fixation of sample (Ethanol/Methanol/Acetone/Paraformaldehyde/Other/Duration etc.)


    Antigen retrieval (Enzymatic method, Heat mediated technique etc.)


    Permeabilization step


    Blocking conditions (Buffer/time period, Blocking agent etc.)


    Primary Antibody (Manufacturer/Species/Diluent/Dilution/Incubation time, Wash step)


    Secondary Antibody (Manufacturer/Species/Diluent/Dilution/Incubation time, Wash step)


    Detection method


    Positive and negative controls used (please specify)


    Optimization attempts (problem solving)
    How many times have you tried the IHC?



    Have you run a "No Primary" control?
    Yes No

    Do you obtain the same results every time?
    Yes No


    What steps have you altered?


    Additional Notes


    We would appreciate if you are also able to provide and image which woudl help us to assess the results

    Read More

    Question
    Answer

    When antibody is anti-IgG (H+L) then it will react with other immunoglobulin classes (IgM, IgA, IgD, IgE) and subclasses since they all share the same light chains (either kappa or lambda). When antibody is Anti-IgG, F(ab')2 - not specific for IgG- they react with light chains, and therefore also react with other immunoglobulin classes (IgA, IgM, IgD, and IgE) and subclasses sharing the same light chains. Other options anti-IgM compatible secondaries besides ab8517 for Flow Cytometry are: ab6785 Goat polyclonal to Mouse IgG - H&L (FITC) ab60313 Goat polyclonal to Mouse IgG (Chromeo™ 488) ab60316 Goat polyclonal to Mouse IgG - H&L (Chromeo™ 546) ab60318 Goat polyclonal to Mouse IgG (Chromeo™ 642) ab6563 and ab7002 are other options. Please bear in mind that the affinity might be lower for IgG H&L antibodies against IgM, therefore the safest would be to use a secondary against IgM.