  • Product name
    Human Angiogenesis Antibody Array - Membrane (23 targets)
    See all Angiogenesis Antibody Array antibody arrays
  • Sample type
    Cell culture supernatant, Saliva, Milk, Urine, Serum, Plasma, Cell culture extracts, Other biological fluids, Whole Blood, Tissue Extracts, Cell Lysate, Cell culture media
  • Assay type
    Semi-quantitative
  • Species reactivity
    Reacts with: Human
  • Product overview

    ab169808 is for simultaneous detection of 23 Human Angiogenic Factors. Suitable for all liquid sample types.


    Targets: Angiopoietin 1, Angiopoietin 2, Angiostatin, Endostatin, G-CSF, GM-CSF, I-309, IL-10, IL-1 alpha, IL-1 beta, IL-2, IL-4, I-TAC, MCP-3, MCP-4, MMP-1, MMP-9, PECAM-1, Tie-2, TNF alpha, uPAR, VEGFR2, VEGFR3


    Cytokine arrays are an antibody-pair-based assay, analogous to ELISA, but using a membrane as a substrate rather than a plate. Capture antibodies are supplied arrayed/spotted on a membrane with each pair of spots representing a different analyte. Sample is added (0.2-1ml of 1 sample to each membrane), and then paired biotinylated detector antibodies and streptavidin HRP. The cytokine array is analyzed using the same methods as a chemiluminescent western blot. Comparison between samples can be by eye or using densitometry software for a semi-quantitative comparison.


    Learn more about membrane antibody arrays

  • Notes

    A table listing all of our human membrane antibody cytokine arrays and other arrays and the analytes they measure is available here.

  • Tested applications
    Suitable for: Multiplex Protein Detectionmore details

Properties

Applications

Our Abpromise guarantee covers the use of ab169808 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
Multiplex Protein Detection Use at an assay dependent concentration.

Images

  • Typical results obtained with Abcam Membrane Antibody Arrays. These membranes were probed with conditioned media from two different cell lines. Membranes were exposed to film at room temperature for 1 minute.

Protocols

References

ab169808 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

There are currently no Questions for ab169808.
Please use the link above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Sign up