Human MMP Antibody Array - Membrane (10 Targets) (ab134004)
Overview
-
Product name
Human MMP Antibody Array - Membrane (10 Targets)
See all MMP Antibody Array antibody arrays -
Sample type
Cell culture supernatant, Saliva, Milk, Urine, Serum, Plasma, Cell culture extracts, Other biological fluids, Whole Blood, Tissue Extracts, Cell Lysate, Cell culture media -
Assay type
Semi-quantitative -
Species reactivity
Reacts with: Human -
Product overview
ab134004 is for simultaneous detection of 7 Human MMPs and 3 TIMPs. Suitable for all sample types.
Targets: MMP-1, MMP-2, MMP-3, MMP-8, MMP-9, MMP-10, MMP-13, TIMP-1, TIMP-2, TIMP-4
Antibody arrays are an antibody-pair-based assay, analogous to ELISA, but using a membrane as a substrate rather than a plate. Capture antibodies are supplied arrayed/spotted on a membrane with each pair of spots representing a different analyte. Sample is added (0.2-1ml of 1 sample to each membrane), and then paired biotinylated detector antibodies and streptavidin HRP. The antibody array is analyzed using the same methods as a chemiluminescent western blot. Comparison between samples can be by eye or using densitometry software for a semi-quantitative comparison.
-
Notes
If you are interested in this antibody array, array ab169816 may also be of interest.
A table of human antibody membrane arrays and the analytes they measure is available here.
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
Tested applications
Suitable for: Multiplex Protein Detectionmore details
Properties
-
Storage instructions
Store at -20°C. Please refer to protocols. -
Components 1 x 4 Membranes 1 x 8 Membranes 1,000X HRP-Conjugated Streptavidin 1 x 50µl 1 x 50µl 20X Wash Buffer I 1 x 10ml 1 x 20ml 20X Wash Buffer II 1 x 10ml 1 x 20ml 2X Cell Lysis Buffer 1 x 10ml 1 x 16ml 8-Well Incubation Tray (with Lid) 1 unit 1 unit Biotin-Conjugated Anti-Cytokines 2 vials 4 vials 1X Blocking Buffer 1 x 25ml 2 x 25ml Cytokine Antibody Array Membranes 4 units 8 units Detection Buffer C 1 x 1.5ml 1 x 2.5ml Detection Buffer D 1 x 1.5ml 1 x 2.5ml -
Research areas
Applications
The Abpromise guarantee
Our Abpromise guarantee covers the use of ab134004 in the following tested applications.
The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.
Application | Abreviews | Notes |
---|---|---|
Multiplex Protein Detection |
Use at an assay dependent concentration.
|
Notes |
---|
Multiplex Protein Detection
Use at an assay dependent concentration. |
Images
-
Human serum and plasma from a pooled donor (n=50) sample was diluted to 25% and assayed using ab134004.
-
Human serum and plasma from a pooled donor (n=50) sample was diluted to 25% and assayed using ab134004. Mean pixel density was quantified using CCD camera software analysis.
-
143B cells (Human osteosarcoma) were seeded at 1x106 cells/mL and cultured in EMEM media supplemented with 10% fetal calf serum, 100 U/mL penicillin, and 100 µg/mL streptomycin sulfate.
Cells were cultured for 48 hours, washed and harvested. Cell and tissue extracts were prepared and 250 µg of total protein was assayed using ab134004.
-
Cells were cultured for 48 hours, washed and harvested. Cell and tissue extracts were prepared and 250 µg of total protein was assayed using ab134004. Mean pixel density was quantified using CCD camera software analysis.
-
Dot Blot - Human MMP Antibody Array - Membrane (10 Targets) (ab134004)This image is courtesy of an anonymous customer.Membranes were probed with media and cell lysate from control and treated MCF-7 cells. These membranes were exposed to film for 1 minute.
Datasheets and documents
-
SDS download
-
Datasheet download
References (11)
ab134004 has been referenced in 11 publications.
- Triebel J et al. Matrix Metalloproteases and Cathepsin D in Human Serum do not Cleave Prolactin to Generate Vasoinhibin. Clin Lab 66:N/A (2020). PubMed: 32390374
- Dias F et al. Plasma Extracellular Vesicle-Derived TIMP-1 mRNA as a Prognostic Biomarker in Clear Cell Renal Cell Carcinoma: A Pilot Study. Int J Mol Sci 21:N/A (2020). PubMed: 32610589
- Cathery W et al. Umbilical Cord Pericytes Provide a Viable Alternative to Mesenchymal Stem Cells for Neonatal Vascular Engineering. Front Cardiovasc Med 7:609980 (2020). PubMed: 33553259
- Balta E et al. Spatial oxidation of L-plastin downmodulates actin-based functions of tumor cells. Nat Commun 10:4073 (2019). PubMed: 31501427
- Lye JJ et al. Astrocyte senescence may drive alterations in GFAPa, CDKN2A p14ARF, and TAU3 transcript expression and contribute to cognitive decline. Geroscience 41:561-573 (2019). PubMed: 31654269