Overview

  • Product name

    Human MMP8 ELISA Kit
    See all MMP8 kits
  • Detection method

    Colorimetric
  • Precision

    Intra-assay
    Sample n Mean SD CV%
    Overall 8 1.7%
    Inter-assay
    Sample n Mean SD CV%
    Overall 3 12.2%
  • Sample type

    Saliva, Serum, Heparin Plasma, EDTA Plasma, Citrate Plasma
  • Assay type

    Sandwich (quantitative)
  • Sensitivity

    19.5 pg/ml
  • Range

    78 pg/ml - 5000 pg/ml
  • Recovery

    Sample specific recovery
    Sample type Average % Range
    Saliva 99.7 86% - 114%
    Serum 84 81% - 86%
    Heparin Plasma 86 82% - 90%
    EDTA Plasma 82 79% - 85%
    Citrate Plasma 85 83% - 87%

  • Assay time

    1h 30m
  • Assay duration

    One step assay
  • Species reactivity

    Reacts with: Human
  • Product overview

    MMP8 in vitro SimpleStep ELISA® (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of MMP8 protein in serum and plasmas, saliva, and synovial fluid.


    The SimpleStep ELISA® employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. TMB substrate is added and during incubation is catalyzed by HRP, generating blue coloration. This reaction is then stopped by addition of Stop Solution completing any color change from blue to yellow. Signal is generated proportionally to the amount of bound analyte and the intensity is measured at 450 nm. Optionally, instead of the endpoint reading, development of TMB can be recorded kinetically at 600 nm.

  • Notes

    Matrix metalloproteinase-8 (MMP8), also known as neutrophil collagenase and PMNL collagenase, is a zinc and calcium binding protein encoded by the gene MMP-8. MMP8 belongs to the matrix metalloproteinase family which are involved in the degradation of extracellular matrix, and are involved in embryonic development, reproduction, and tissue remolding. MMP8 is stored inactive in granules within neutrophils, and upon secretion is activated by cleavage of a peptide through the dissociation of a conserved cysteine from a zinc ion. MMP8 degrades type I, II, and III collagens, and the protein contains four hemopexin regions.

  • Tested applications

    Suitable for: Sandwich ELISAmore details
  • Platform

    Pre-coated microplate (12 x 8 well strips)

Properties

Associated products

Applications

Our Abpromise guarantee covers the use of ab219050 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
Sandwich ELISA Use at an assay dependent concentration.

Images

  • SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.

     

  • Background-subtracted data values (mean +/- SD) are graphed.

  • Standard curve comparison between human MMP8 SimpleStep ELISA® kit and traditional ELISA kit from leading competitor. SimpleStep ELISA kit shows comparable sensitivity.

  • The concentrations of MMP8 were measured in duplicate, interpolated from the MMP8 standard curves and corrected for sample dilution. Undiluted samples are as follows: saliva 37.5%, synovial fluid 12.5%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean MMP8 concentrations were determined to be 15.4 ng/mL in saliva and 19.2 ng/mL in synovial fluid.

  • The concentrations of MMP8 were measured in duplicate, interpolated from the MMP8 standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 1.25%, plasma (citrate) 1.25%, plasma (EDTA) 1.25%, plasma (heparin) 1.25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Native signal was undetectable in null-spiked samples.

Protocols

References

ab219050 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

There are currently no Customer reviews or Questions for ab219050.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com