Overview

  • Product name

    Human VE Cadherin ELISA Kit
    See all VE Cadherin kits
  • Detection method

    Colorimetric
  • Precision

    Intra-assay
    Sample n Mean SD CV%
    EDTA plasma 5 5.3%
    Inter-assay
    Sample n Mean SD CV%
    EDTA plasma 3 10.1%
  • Sample type

    Cell culture supernatant, Urine, Serum, Plasma
  • Assay type

    Sandwich (quantitative)
  • Sensitivity

    331 pg/ml
  • Range

    0.63 ng/ml - 40 ng/ml
  • Recovery

    Sample specific recovery
    Sample type Average % Range
    Cell culture supernatant 119 112% - 115%
    Serum 99 91% - 103%
    Heparin Plasma 116 110% - 121%
    EDTA Plasma 99 96% - 101%
    Citrate Plasma 94 84% - 99%

  • Assay time

    1h 30m
  • Assay duration

    One step assay
  • Species reactivity

    Reacts with: Human
    Does not react with: Mouse, Rat, Cow
  • Product overview

    VE Cadherin in vitro SimpleStep ELISA® (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of VE Cadherin protein in human serum, plasma, urine and cell culture supernatant.


    The SimpleStep ELISA® employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material.  TMB substrate is added and during incubation is catalyzed by HRP, generating blue coloration. This reaction is then stopped by addition of Stop Solution completing any color change from blue to yellow. Signal is generated proportionally to the amount of bound analyte and the intensity is measured at 450 nm. Optionally, instead of the endpoint reading, development of TMB can be recorded kinetically at 600 nm.

  • Notes

    VE-Cadherin (also known as Cadherin 5 or CD144) is a calcium dependent cell-cell adhesion glycoprotein. VE-Cadherin is a member of the cadherin superfamily, which interact with themselves in connecting cells. VE-Cadherin is expressed in endothelial cells and has role establishing and maintaining endothelial polarity and intercellular junctions.

  • Tested applications

    Suitable for: Sandwich ELISAmore details
  • Platform

    Pre-coated microplate (12 x 8 well strips)

Properties

Applications

Our Abpromise guarantee covers the use of ab210968 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
Sandwich ELISA Use at an assay dependent concentration.

Images

  • SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.

     

  • Background-subtracted data values (mean +/- SD) are graphed.

  • The concentrations of VE-Cadherin were measured in duplicates, interpolated from the VE-Cadherin standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 1:100 and plasma (heparin) 1:67. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean VE-Cadherin concentration was determined to be 919 ng/mL in serum and 1,400 ng/mL in plasma (heparin).

  • The concentrations of VE-Cadherin were measured in duplicates, interpolated from the VE-Cadherin standard curves and corrected for sample dilution. Undiluted samples are as follows: plasma (citrate) 1:100 and plasma (EDTA) 1:67. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean VE-Cadherin concentration was determined to be 1091 ng/mL in plasma (citrate) and 809 ng/mL in plasma (EDTA).

  • Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean VE-Cadherin concentration was determined to be 908 ng/mL with a range of 628 – 1,527 ng/mL

Protocols

References

This product has been referenced in:

  • Meng D  et al. Effects of VEGFR1+ hematopoietic progenitor cells on pre-metastatic niche formation and in vivo metastasis of breast cancer cells. J Cancer Res Clin Oncol 145:411-427 (2019). Read more (PubMed: 30483898) »
  • Ishii D  et al. Marked Changes in Blood-Brain Barrier Biomarkers After Direct Bypass Surgery for Moyamoya Angiopathy: Preliminary Study. World Neurosurg 120:e611-e616 (2018). Read more (PubMed: 30165210) »
See all 2 Publications for this product

Customer reviews and Q&As

There are currently no Customer reviews or Questions for ab210968.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com