Overview

  • Product name
  • Description
    Rabbit polyclonal to KIF17
  • Host species
    Rabbit
  • Tested applications
    Suitable for: WB, ICC/IF, IHC-Fr, IHC-Pmore details
  • Species reactivity
    Reacts with: Mouse, Dog, Human
  • Immunogen

    Synthetic peptide corresponding to Mouse KIF17 aa 589-606 (C terminal) conjugated to keyhole limpet haemocyanin.

  • Positive control
    • Mouse brain cytosolic fraction, PC12 cell line differentiated with NGF.
  • General notes
    Storage in frost-free freezers is not recommended. If slight turbidity occurs upon prolonged storage, clarify the solution by centrifugation before use.

Properties

Applications

Our Abpromise guarantee covers the use of ab11261 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
WB 1/1000. Predicted molecular weight: 170 kDa.
ICC/IF Use at an assay dependent concentration.
IHC-Fr Use at an assay dependent concentration.
IHC-P 1/300.

Target

References

This product has been referenced in:
  • Lim YS & Tang BL A role for Rab23 in the trafficking of Kif17 to the primary cilium. J Cell Sci 128:2996-3008 (2015). Read more (PubMed: 26136363) »
  • Jiang L  et al. Kinesin family 17 (osmotic avoidance abnormal-3) is dispensable for photoreceptor morphology and function. FASEB J 29:4866-80 (2015). Read more (PubMed: 26229057) »
See all 12 Publications for this product

Customer reviews and Q&As

1-2 of 2 Abreviews or Q&A

Answer

Thank you for calling us yesterday to report your concerns over the specificity of theanti-alpha tubulin antibody (ab4074) as well as the changes in our vial sizes you have noticed.

As discussed over the phone, from time totime we do need to change the sizes we provide of our products. This is not a universal strategy in order to make more money from our products but due to a number of different reasons, often outside of our own control. For example, sometimes an antibody which was being produced in good scale becomes more difficult to produce and/or characteriseand we therefore need to reduce the quantity provided as it no longer becomes financially viable to provide it in the same size. We constantly review such factors and try our best to take customeropinion into consideration. Therefore, if you could provide me with a list of the antibodies you are no longer satisfied with due to the change in size provided I would be grateful. I can then pass this on to the relevant people within Abcam to look into why these changes have been made and if we can do anything to amend the change.

As discussed over the phone, I have also sent out a newvial of theanti-KIF17antibody(ab11261) to you. This should be with you today. In order to understand your concerns further, could you briefly explain how you have been using this antibody? Are you again performing ICC? In a 1/100 dilution? I have also arranged for the order of anti-alpha tubulin (ab4074) to be refunded.

I am going to contact the lab over how the anti-ensconsin fastrack antibody (ab79124) is being dealt with. I have looked through your correspondence with my colleague Miia about this antibody and understand your concerns over its specificity. I will get back to you as soon as I have further information relating to this.

I look forward to receiving your reply.

Read More

Question
Answer

Thank you for confirming these details and for your cooperation. The details provided enable us to closely monitor the quality of our products. I am sorry this product did not perform as stated on the datasheet and for the inconvenience this has caused. As requested, I have issued a free of charge replacement. To check the status of the order please contact our Customer Service team and reference this number. Please note that this free of charge replacement vial is also covered by our Abpromise guarantee. Should you still be experiencing difficulties, or if you have any further questions, please do not hesitate to let us know. I wish you the best of luck with your research.

Read More

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"