AB312830

APC-iFluor® 700 Conjugation Kit

Be the first to review this product! 리뷰 제출

|

(0 출판물)

APC-iFluor® 700 Conjugation Kit (ab312830) offers several standout features:

- Rapid Conjugation: achieve APC-iFluor® 700 labeling in under 2 hours with minimal hands-on time. APC-iFluor® 700 is an alternative to APC-Alexa® 700.
- Labels up to 100 µg antibody.
- Versatility: suitable for conjugating antibodies and proteins. APC-iFluor® 700 – tandem dye labeled antibodies can be used immediately in applications such as Flow cytometry, ICC/IF, ELISA and other fluorescence imaging assays without further purification.
3 이미지
Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)
  • Flow Cyt

Supplier Data

Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)

Flow cytometry analysis of whole blood stained with APC-iFluor® 700 anti-human CD4 *SK3* conjugate prepared using the iAPC-iFluor® 700 Conjugation Kit (ab312830 & ab312831). The fluorescence signal was monitored using an Aurora flow cytometer in the APC-iFluor® 700-specific R4-A channel.

Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)
  • Flow Cyt

Supplier Data

Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)

Flow cytometric analysis of APC-iFluor® 700 (Red Bar) or APC-Alexa Fluor® 700 (Blue Bar) anti-human CD8 on human lymphocytes. Whole blood was stained with ab312830 or APC-Alexa Fluor® 700 anti-human CD8 and compared to whole blood stained with a APC-iFluor® 700 and APC-Alexa Fluor® 700 mouse IgG control. Flow cytometry was performed on a ACEA flow cytometry system.

Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)
  • Flow Cyt

Supplier Data

Flow Cytometry - APC-iFluor® 700 Conjugation Kit (AB312830)

Flow cytometry analysis of PBMC stained with APC-iFluor® 700 anti-human CD4 *RPA-T4* conjugate. The fluorescence signal was monitored using an Aurora flow cytometer in the APC-iFluor® 700 specific R4-A channel.

주요 정보

검출 방식

Fluorescent

제품 세부 정보

APC-iFluor® 700 Conjugation Kit provides a convenient method for labelling small amounts of monoclonal, polyclonal antibodies or other proteins (>10 kDa) with the Red Laser-excitable XFD750. This dye has a fluorescence maxima (Ex/Em) of 651/713 nm respectively. These characteristics make APC-iFluor® 700 Tandem an excellent replacement for APC-Alexa Fluor® 700 Tandem, since they have almost identical spectra. APC-iFluor® 700 Tandem is a stable dye and shows good reactivity and selectivity with protein amino groups.

This conjugation kit has all the essential components to perform two separate labelling reactions with no column purification needed. Each of the two vials of APC-iFluor® 700 Tandem provided in the kit is optimized for labelling ~50 μg antibody.

Impure antibodies or antibodies stabilized with bovine serum albumin (BSA) or gelatin will not be labelled well, Abcam offers a range of purification kits

제품 구성

{ "values": { "100g": { "sellingSize": "100 µg", "publicAssetCode":"ab312830-100ug", "assetComponentDetails": [ { "size":"1 x 1 Vial", "name":"MTA", "number":"AB312830-CMP05" }, { "size":"1 x 2 Vial", "name":"FOL-Activated APC-iFluor™ 700", "number":"AB312830-CMP04" }, { "size":"1 x 20 µL", "name":"Reaction Buffer", "number":"AB312830-CMP03" } ] }, "50g": { "sellingSize": "50 µg", "publicAssetCode":"ab312830-50ug", "assetComponentDetails": [ { "size":"1 x 2 Vial", "name":"MTA", "number":"AB312830-CMP05", "productcode":"" }, { "size":"1 x 2 Vial", "name":"FOL-Activated APC-iFluor™ 700", "number":"AB312830-CMP04", "productcode":"" }, { "size":"1 x 20 µL", "name":"Reaction Buffer", "number":"AB312830-CMP03", "productcode":"" } ] } } }

특성 및 보관 정보

배송 시 보관 조건
Ambient - Can Ship with Ice
적절한 단기 보관 조건
+4°C
적절한 장기 보관 조건
+4°C
보관 정보
+4°C

제품 프로토콜

타겟 정보

websiteProtocolBooklet
en

Product promise

저희는 고품질 시약으로 고객님의 연구를 서포트하고자 최선을 다하고 있으며, 모든 단계에서 함께 하겠습니다. 만약 제품이 기대한 성능을 보이지 않을 경우에도 Product Promise로 보호받으실 수 있습니다.
자세한 내용은 이용 약관을 확인해 주세요.

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com