DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) offers several standout features:

- Rapid Conjugation: achieve DyLight® 488 labeling in under 20 minutes with just 30 seconds of hands-on time.
- High Efficiency: ensures 100% antibody recovery, meaning no loss of valuable antibodies.
- Versatility: suitable for conjugating antibodies, proteins, and peptides. DyLight® 488 labeled antibodies can be used immediately in applications such as Western blot (WB), ELISA, and Immunohistochemistry (IHC) without further purification.
- Confidence: cited in over 30 publications.
8 이미지
Flow Cytometry - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Flow Cyt

PubMed

Monaco, Sara, et al used DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) as part of examining the co-localization of Smoothened and AC3 in primary cilia. They used the kit to conjugate DyLight® 488 to anti-AC3 antibody for use in flow cytometry.
(A) Representative dot plots of untreated (Control) and SAG-treated samples (SAG) from E18 embryos immunostained for AC3-FITC and Smoothened-APC (Smo-APC). (B) Quantification of the percentage of Smo+AC3+ particles. Bar graphs show mean ± SEM, p-values are calculated with Student's t-test. Statistically significant differences are indicated with asterisks (*p < 0.05, **p < 0.01).

Image from Monaco, Sara, et al., Front Cell Neurosci., 12:519; doi: 10.3389/fncel.2018.00519. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Schematic Diagram - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Schematic Diagram

Supplier Data

This illustration demonstrates a general procedure of how the Lightning-Link®(Fast) labeling technology enables the direct labeling of antibodies or proteins.

Simply pipette your antibody or biomolecule of choice into the vial of a lyophilized mixture containing the label of interest and incubate for just 15 minutes. Please see the ab201799 protocol booklet for more details.

Learn more about our Lightning-Link® conjugation kits here

Fluorescence Microscopy - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Fluorescence Microscopy

PubMed

Lalo, Ulyana, et al used DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) as part of examining the colocalization of vesicular ATP transporters with exocytotic organelle markers. They used the kit to conjugate DyLight® 488 to various antibodies for use in multiphoton fluorescent microscopy.
Living, acutely isolated cortical astrocytes were labeled with antibodies to vesicular transporters (VNUT1 and VGLUT1) and synaptic vesicle (SV2A) and lysosomal (LAMP3 and Cathepsin-D) markers. Antibodies were conjugated to fluorescent dyes DyLight488 (green) and DyLight594 (red) prior to astrocyte labeling. (A-D) The representative two-photon fluorescence images (maximal intensity projections of Z-stack) and results of colocalization analysis, carried out using NIH ImageJ 1.43 software. The correlation between green and red fluorescence (images in the right column) is depicted as a product of the relative differences from the mean (PDM) for each pixel; the pseudocolor PDM images were generated as an output of ImageJ analysis routine. Positive values (bright yellow) are indicative for good co-localization of green and red signals, negative values (blue-violet) indicate segregation, and black color shows the lack of correlation. Note the different extent of scale for PDM values in (A-D). All scale bars in (A-D) are 5 μm.

Image from Lalo, Ulyana, et al., PLoS Biol., 12(1): e1001747; doi: 10.1371/journal.pbio.1001747. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Flow Cytometry - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Flow Cyt

PubMed

Dorfmueller, Simone, et al used DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) as part of characterizing antibody-labelled human corneal endothelial cells (hCECs) and stromal fibroblasts. They used the kit to conjugate DyLight® 488 to C1M2-2-B8 scFv or IgG-B8 full-size antibody for use in flow cytometry.
Primary hCECs or stromal fibroblasts were incubated with C1M2-2-B8 scFv or IgG-B8 full-size antibody conjugated to DyLight® 488 (4 μg/ml). (a) The histogram for unlabelled hCECs (black) is overlaid with those for scFv and IgG-B8 labelled cells as indicated. Similarly, the histogram for unlabelled stromal fibroblasts (orange) is overlaid with those for scFv and IgG-B8 labelled fibroblasts. (b) The histograms for C1M2-2-B8 scFv labelled hCECs and stromal fibroblasts were shown on the same graph, as for the histograms for IgG-B8 labelled hCECs and stromal fibroblasts. The peak separation between fibroblasts and hCECs were similar in magnitude with either scFv or IgG labelling.

Image from Dorfmueller, Simone, et al., Sci rep., 6:21661; doi: 10.1038/srep21661. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Other - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Other

Lab

Representative image of DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799)

Components shown from left to right :

DyLight® 488 mix (3 vials for 3x 10 µg, 3x 100 µg)

Modifier reagent (1 vial)

Quencher reagent (1 vial)

Securitainer

Note : The vial labels shown in this image use generic names for illustrative purposes only and may not exactly match the specific component names included in the conjugation kit.

Note : Color of the lyophilized material in image may not precisely match the color shade in the actual kit.

Other - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Other

Lab

Representative image of DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799)

Components shown from left to right :

DyLight® 488 mix (1 vial for 100 µg, 1 mg)

Modifier reagent (1 vial)

Quencher reagent (1 vial)

Securitainer

Note : The vial labels shown in this image use generic names for illustrative purposes only and may not exactly match the specific component names included in the conjugation kit.

Note : Color of the lyophilized material in image may not precisely match the color shade in the actual kit.

Conjugation - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Conjugation

PubMed

Mellema, M., et al used DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) as part of examining DyLight® 488-conjugated alendronate binding of calcifying nanoparticles (CNP) generated in vitro. They used the kit to conjugate DyLight® 488 to alendronate (that selectively and specifically bind to calcium-phosphorus surfaces) for use in Nanoparticle Tracking Analysis (NTA®).
CNP in the whole urine samples and in vitro generated CNP suspensions were analyzed using the NanoSight LM10HS-48814TS instrument (Malvern Instruments, Worcestershire, UK) with a 488 nm wavelength laser, fluorescent filter (505 nm long pass), and both temperature control and syringe pump modules. A representative histogram shows averaged sizing and relative abundance data (left; SE in red) and individual analyses from the assessment (right) of this representative sample in triplicate. Note that CNP generated in vitro do not acquire the protein/mucus coating known to occur in vivo and the larger forms retain the ability to bind to alendronate.

Image from Mellema et al., PLoS One, 11(12):e0166045; doi: 10.1371/journal.pone.0166045. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Conjugation - DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (AB201799)
  • Conjugation

PubMed

DyLight® 488 Conjugation Kit - Lightning-Link® labeling alendronate compound and osteopontin protein for Nanoparticle Tracking Analysis (NTA®).

Mellema M et al. used ab201799 as part of examining mineralo-organic nanoparticles in feline urine.

They used the kit to conjugate DyLight® 488 to alendronate compound and osteopontin protein for use in Nanoparticle Tracking Analysis (NTA®).

A : Representative histogram showing size distribution and cumulative percentage (left) of submicron particulate matter in healthy feline urine after labeling with DyLight 488 conjugated alendronate. A representative frame from the captured video analyzed by NTA is shown as well (right). Note the strongly preferential binding to primary CNP that lack an outer layer of protein or mucus.

B : Representative histogram showing averaged sizing and relative abundance data (left; SE in red) and individual analyses from the assessment (right) of this representative sample of healthy feline urine after labeling with DyLight 488 conjugated osteopontin. Note the strongly preferential binding to primary naturally-occurring CNP that lack an outer layer of protein or mucus.

Image from Mellema M et al., PloS One,11(12):e0166045. Fig 4.; doi: 10.1371/journal.pone.0166045. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

주요 정보

제품 세부 정보

DyLight® 488 Conjugation Kit (Fast) - Lightning-Link® (ab201799) uses a simple and quick process for labeling / conjugation of antibodies. It can also be used to conjugate other proteins or peptides.

To conjugate an antibody to DyLight® 488 using this kit:
- add modifier to antibody and incubate for 15 min
- add quencher and incubate for 5 min

The DyLight® 488 conjugated antibody can be used immediately in Flow cytometry, WB, ELISA, IHC etc. No further purification is required and 100% of the antibody is recovered for use.

Learn about our antibody labeling kits and their advantages here.

Learn about buffer compatibility below; for incompatible buffers and low antibody concentrations, use our antibody purification and concentration kits.
Custom size conjugation kits up to 100 mg are available on demand. Please contact us to discuss your requirements.

Amount and volume of antibody for conjugation to Dylight ® 488

Kit size Recommended
amount of antibody1
Maximum
amount of antibody
Maximum antibody
volume2
3 x 10 µg 3 x 10 µg 3 x 20 µg 3 x 10 µL
100 µg 1 x 100 µg 1 x 200 µg 1 x 100 µL
3 x 100 µg 3 x 100 µg 3 x 200 µg 3 x 100 µL
1 mg 1 x 1 mg 1 x 2 mg 1 x 1 mL

1 Using the maximum amount of antibody may result in less labelling per antibody.
2 Ideal antibody concentration is 1mg/mL. 0.5 - 1 mg/mL can be used if the maximum antibody volume is not exceeded. Antibodies > 2 mg/mL or < 0.5 mg/mL should be diluted /concentrated.

Buffer Requirements for Conjugation

Buffer should be pH 6.5-8.5.

Compatible buffer constituents
If a concentration is shown, then the constituent should be no more than the concentration shown. If several constituents are close to the limit of acceptable concentration, then this can inhibit conjugation.

50mM / 0.6% Tris1 0.1% BSA2 50% glycerol
0.1% sodium azide PBS Potassium phosphate
Sodium chloride HEPES Sucrose
Sodium citrate EDTA Trehalose

1 Tris buffered saline is almost always ≤ 50 mM / 0.6%
2 BSA can also interfere with the use of the conjugated antibody in tissue staining.

Incompatible buffer constituents

Thiomerosal Proclin Glycine
Arginine Glutathione DTT

If a constituent of the buffer containing your antibody or protein is not listed above, please contact us.

Only purified antibodies are suitable for use, ie. where other proteins, peptides, or amino acids are not present: antibodies in ascites fluid, serum or hybridoma culture media are incompatible.

Storing and handling conjugation kits

Lyophilized Lightning-Link® components are hygroscopic.

Kits are intentionally shipped at ambient temperature with silica gel to avoid exposure to moisture. Upon receipt, store the kit frozen and protect from moisture. Before opening the outer container, allow the lyophilized components to reach room temperature to minimize condensation.

DyLight® is a trademark of Thermo Fisher Scientific Inc. and its subsidiaries.

This product is manufactured by Expedeon, an Abcam company, and was previously called Lightning-Link® Rapid DyLight® 488 Labeling Kit. 322-0015 is the same as the 1 mg size. 322-0030 is the same as the 3 x 10 µg size. 322-0010 is the same as the 3 x 100 µg size. 322-0005 is the same as the 100 µg size.

제품 구성

{ "values": { "3x10g": { "sellingSize": "3 x 10 µg", "publicAssetCode":"ab201799-3x10ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201799-CMP01" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201799-CMP02" }, { "size":"3 x 10 µg", "name":"Dylight® 488 Conjugation Mix", "number":"AB201799-CMP03" } ] }, "3x100g": { "sellingSize": "3 x 100 µg", "publicAssetCode":"ab201799-3x100ug", "assetComponentDetails": [ { "size":"3 x 100 µg", "name":"Dylight® 488 Conjugation Mix", "number":"AB201799-CMP03" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201799-CMP02" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201799-CMP01" } ] }, "1mg": { "sellingSize": "1 mg", "publicAssetCode":"ab201799-1mg", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201799-CMP02" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201799-CMP01" }, { "size":"1 x 1 mg", "name":"Dylight® 488 Conjugation Mix", "number":"AB201799-CMP03" } ] }, "100g": { "sellingSize": "100 µg", "publicAssetCode":"ab201799-100ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201799-CMP01", "productcode":"" }, { "size":"1 x 100 µg", "name":"Dylight® 488 Conjugation Mix", "number":"AB201799-CMP03", "productcode":"" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201799-CMP02", "productcode":"" } ] } } }

특성 및 보관 정보

배송 시 보관 조건
Ambient - Cannot Ship with Ice
적절한 단기 보관 조건
-20°C
적절한 장기 보관 조건
-20°C
보관 정보
-20°C

제품 프로토콜

타겟 정보

제품이 사용된 논문 (37)

Recent publications for all applications. Explore the 전체 목록 and refine your search

iScience 27:110620 PubMed39252972

2024

Spatial characterization and stratification of colorectal adenomas by deep visual proteomics.

Applications

Unspecified application

Species

Unspecified reactive species

Sonja Kabatnik,Frederik Post,Lylia Drici,Annette Snejbjerg Bartels,Maximilian T Strauss,Xiang Zheng,Gunvor I Madsen,Andreas Mund,Florian A Rosenberger,José Moreira,Matthias Mann

BMC veterinary research 20:372 PubMed39160565

2024

Proneurogenic actions of follicle-stimulating hormone on neurospheres derived from ovarian cortical cells in vitro.

Applications

Unspecified application

Species

Unspecified reactive species

Alfredo González-Gil,Belén Sánchez-Maldonado,Concepción Rojo,Miguel Flor-García,Felisbina Luisa Queiroga,Susana Ovalle,Ricardo Ramos-Ruiz,Manuel Fuertes-Recuero,Rosa Ana Picazo

The Journal of clinical investigation 134: PubMed38954588

2024

Inhibiting the NADase CD38 improves cytomegalovirus-specific CD8+ T cell functionality and metabolism.

Applications

Unspecified application

Species

Unspecified reactive species

Nils Mülling,Felix M Behr,Graham A Heieis,Kristina Boss,Suzanne van Duikeren,Floortje J van Haften,Iris N Pardieck,Esmé Ti van der Gracht,Ward Vleeshouwers,Tetje C van der Sluis,J Fréderique de Graaf,Dominique Mb Veerkamp,Kees Lmc Franken,Xin Lei,Lukas van de Sand,Sjoerd H van der Burg,Marij Jp Welters,Sebastiaan Heidt,Wesley Huisman,Simon P Jochems,Martin Giera,Oliver Witzke,Aiko Pj de Vries,Andreas Kribben,Bart Everts,Benjamin Wilde,Ramon Arens

Frontiers in endocrinology 14:1160155 PubMed37415667

2023

Impaired mitochondrial dynamics and removal of the damaged mitochondria in diabetic retinopathy.

Applications

Unspecified application

Species

Unspecified reactive species

Kumari Alka,Jay Kumar,Renu A Kowluru

Nature communications 14:1910 PubMed37024468

2023

Tryptase β regulation of joint lubrication and inflammation via proteoglycan-4 in osteoarthritis.

Applications

Unspecified application

Species

Unspecified reactive species

Nabangshu Das,Luiz G N de Almeida,Afshin Derakhshani,Daniel Young,Kobra Mehdinejadiani,Paul Salo,Alexander Rezansoff,Gregory D Jay,Christian P Sommerhoff,Tannin A Schmidt,Roman Krawetz,Antoine Dufour

Nature communications 13:6275 PubMed36271092

2022

Single cell transcriptomic profiling of a neuron-astrocyte assembloid tauopathy model.

Applications

Unspecified application

Species

Unspecified reactive species

Hannah Drew Rickner,Lulu Jiang,Rui Hong,Nicholas K O'Neill,Chromewell A Mojica,Benjamin J Snyder,Lushuang Zhang,Dipan Shaw,Maria Medalla,Benjamin Wolozin,Christine S Cheng

International journal of biological sciences 18:6008-6019 PubMed36439874

2022

Endocytosis of Peptidase Inhibitor SerpinE2 promotes Myocardial Fibrosis through activating ERK1/2 and β-catenin Signaling Pathways.

Applications

Unspecified application

Species

Unspecified reactive species

Chao Li,Li-Fang Lv,Mu-Ge Qi-Li,Rui Yang,Yu-Jing Wang,Shuang-Shuang Chen,Ming-Xiu Zhang,Tian-Yu Li,Tong Yu,Yu-Hong Zhou,Hai-Hai Liang,Hong-Li Shan,Xue-Lian Li

JCI insight 7: PubMed35862218

2022

ARMC5-CUL3 E3 ligase targets full-length SREBF in adrenocortical tumors.

Applications

Unspecified application

Species

Unspecified reactive species

Yosuke Okuno,Atsunori Fukuhara,Michio Otsuki,Iichiro Shimomura

Viruses 14: PubMed35458569

2022

Foot-and-Mouth Disease Virus 3A Hijacks Sar1 and Sec12 for ER Remodeling in a COPII-Independent Manner.

Applications

Unspecified application

Species

Unspecified reactive species

Heng-Wei Lee,Yi-Fan Jiang,Hui-Wen Chang,Ivan-Chen Cheng

Methods in molecular biology (Clifton, N.J.) 2258:171-192 PubMed33340361

2020

Directed Differentiation of Human Pluripotent Stem Cells for the Generation of High-Order Kidney Organoids.

Applications

Unspecified application

Species

Unspecified reactive species

Idoia Lucía Selfa,Maria Gallo,Nuria Montserrat,Elena Garreta
제품이 사용된 논문 모두 보기
websiteProtocolBooklet
en
websiteProtocolBooklet
zh

Product promise

저희는 고품질 시약으로 고객님의 연구를 서포트하고자 최선을 다하고 있으며, 모든 단계에서 함께 하겠습니다. 만약 제품이 기대한 성능을 보이지 않을 경우에도 Product Promise로 보호받으실 수 있습니다.
자세한 내용은 이용 약관을 확인해 주세요.

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com