Human Antithrombin III ELISA Kit is a Sandwich ELISA for the measurement of Human Antithrombin III in Human in Biofluids samples.
7 이미지
Sandwich ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • sELISA

Supplier Data

Sandwich ELISA - Human Antithrombin III ELISA Kit (AB108801)

Representative standard curve using ab108801.

Sandwich ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • sELISA

Supplier Data

Sandwich ELISA - Human Antithrombin III ELISA Kit (AB108801)

Representative standard curve using ab108801.

ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • ELISA

Lab

ELISA - Human Antithrombin III ELISA Kit (AB108801)

ELISA : Antithrombin III Human ELISA Kit.

Antithrombin III in human biological fluids (duplicates +/- SD). The samples were differently diluted (serum and Li-heparine plasma : 1e4-1e5; CSF : 1e2-1e3; milk : 10-100; saliva : 5-100; urine : neat).

ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • ELISA

Lab

ELISA - Human Antithrombin III ELISA Kit (AB108801)

ELISA : Antithrombin III Human ELISA Kit.

Linearity : Antithrombin III in samples at different diutions, corrected for the factor of dilution (duplicates +/- SD), showing ng x mL-1 on y-axis.

ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • ELISA

Lab

ELISA - Human Antithrombin III ELISA Kit (AB108801)

ELISA : Antithrombin III Human ELISA Kit.

Linearity : Antithrombin III in samples at different diutions, corrected for the factor of dilution (duplicates +/- SD).

ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • ELISA

Lab

ELISA - Human Antithrombin III ELISA Kit (AB108801)

ELISA : Antithrombin III Human ELISA Kit.

Antithrombin III in cell culture supernatants (duplicates +/- SD), tested in the dilution range of 1 : 1-1 : 100.

ELISA - Human Antithrombin III ELISA Kit (AB108801)
  • ELISA

Lab

ELISA - Human Antithrombin III ELISA Kit (AB108801)

ELISA : Antithrombin III Human ELISA Kit.

Linearity : Antithrombin III in samples at different diutions, corrected for the factor of dilution (duplicates +/- SD).

주요 정보

검출 방식

Colorimetric

샘플 타입

Cerebral Spinal Fluid, Milk, Plasma, Saliva, Serum, Urine

Reacts with

Human

분석 유형

Sandwich

결과 유형

Quantitative

Sensitivity

= 0.99 ng/mL

검출 범위

1.563 - 100 ng/mL

분석 소요 시간

4h

분석 플랫폼

Microplate

Reactivity 정보

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "sELISA": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

제품 세부 정보

Abcam's Antithrombin III Human in vitro ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of Antithrombin III in urine, plasma, milk, saliva, cerebrospinal fluid, serum, and cell culture supernatants.

An antithrombin III specific antibody has been precoated onto 96-well plates and blocked. Standards or test samples are added to the wells and subsequently an antithrombin III specific biotinylated detection antibody is added and then followed by washing with wash buffer. Streptavidin-Peroxidase Complex is added and unbound conjugates are washed away with wash buffer. TMB is then used to visualize Streptavidin-Peroxidase enzymatic reaction. TMB is catalyzed by Streptavidin-Peroxidase to produce a blue color product that changes into yellow after adding acidic stop solution. The density of yellow coloration is directly proportional to the amount of antithrombin III captured in plate.

The entire kit may be stored at -20°C for long term storage before reconstitution - Avoid repeated freeze-thaw cycles.

Precision

[ { "reproducibilityType": "Intra", "sample": "Overall", "replicates": 0, "mean": null, "standardDeviation": null, "coefficientOfVariability": "4" }, { "reproducibilityType": "Inter", "sample": "Overall", "replicates": 0, "mean": null, "standardDeviation": null, "coefficientOfVariability": "10.6" } ]

제품 구성

{ "values": { "1x96Tests": { "sellingSize": "1 x 96 Tests", "publicAssetCode":"ab108801-1x96Tests", "assetComponentDetails": [ { "size":"2 x 30 mL", "name":"20X Wash Buffer Concentrate", "number":"AB108801-CMP06", "productcode":"" }, { "size":"1 x 11 mL", "name":"Stop Solution", "number":"AB108801-CMP08", "productcode":"" }, { "size":"1 x 30 mL", "name":"10X Diluent N Concentrate", "number":"AB108801-CMP02", "productcode":"" }, { "size":"1 x 7 mL", "name":"Chromogen Substrate", "number":"AB108801-CMP03", "productcode":"" }, { "size":"1 x 1 Unit", "name":"Antithrombin III Microplate (12 x 8 well strips)", "number":"AB108801-CMP04", "productcode":"" }, { "size":"3 x 1 Unit", "name":"Sealing Tapes", "number":"AB108801-CMP07", "productcode":"" }, { "size":"1 x 80 µL", "name":"100X Streptavidin-Peroxidase Conjugate", "number":"AB108801-CMP09", "productcode":"" }, { "size":"1 x 1 Vial", "name":"Antithrombin III Standard", "number":"AB108801-CMP05", "productcode":"" }, { "size":"1 x 120 µL", "name":"50X Biotinylated Human Antithrombin III Antibody", "number":"AB108801-CMP01", "productcode":"" } ] } } }

특성 및 보관 정보

배송 시 보관 조건
Blue Ice
적절한 단기 보관 조건
-20°C
적절한 장기 보관 조건
Multi
보관 정보
Please refer to protocols

추가 정보

This supplementary information is collated from multiple sources and compiled automatically.

Antithrombin III also known as ATIII or antithrombin 3 is a glycoprotein with a mass of approximately 58 kDa. This protein is mainly synthesized in the liver and circulates in the blood plasma. Antithrombin III functions as a serine protease inhibitor targeting and inhibiting several key enzymes involved in blood coagulation including thrombin and Factor Xa. Its activity is influenced by the presence of heparin which increases its inhibitory effects on these enzymes. This interaction is essential for regulating blood clot formation and maintaining hemostatic balance.
Biological function summary

Antithrombin III plays a critical role in blood clotting by specifically inhibiting clotting factors. It forms complexes with its target enzymes leading to their inactivation and preventing excessive thrombin production. The protein does not form part of larger complexes but acts independently to exert its anticoagulant function. The normal range for antithrombin 3 levels in plasma is important for ensuring a balanced blood coagulation system. Its function helps prevent inappropriate clot formation and ensures smooth blood flow through the circulatory system.

Pathways

Antithrombin III is integral to the coagulation cascade. It is primarily involved in the intrinsic and common coagulation pathways where it regulates thrombin and Factor Xa activity. This regulation prevents the unchecked formation of fibrin clots which can lead to thrombosis. ATIII works closely with proteins like heparin cofactor II and protein C which also modulate the coagulation pathway emphasizing its role in maintaining hemostatic balance. Its function is essential in controlling the coagulation cascade and ensuring that it proceeds appropriately without leading to pathology.

Antithrombin III deficiency can lead to coagulation disorders such as thrombophilia characterized by an increased risk of forming clots. Inherited or acquired deficiencies in antithrombin 3 can result in life-threatening thrombotic events. Furthermore liver diseases which affect the production of ATIII can also result in decreased antithrombin activity compounding coagulation problems. Other proteins related to this process include protein S and plasminogen which also play roles in clot regulation and fibrinolysis. Understanding the connection of antithrombin III to these pathways and diseases is important for developing effective therapeutic strategies.

제품 프로토콜

타겟 정보

Most important serine protease inhibitor in plasma that regulates the blood coagulation cascade (PubMed : 15140129, PubMed : 15853774). AT-III inhibits thrombin, matriptase-3/TMPRSS7, as well as factors IXa, Xa and XIa (PubMed : 15140129). Its inhibitory activity is greatly enhanced in the presence of heparin.
See full target information SERPINC1

대체 명칭 보기

AT3, PRO0309, SERPINC1, Antithrombin-III, ATIII, Serpin C1

제품이 사용된 논문 (3)

Recent publications for all applications. Explore the 전체 목록 and refine your search

Bioactive materials 45:181-200 PubMed39651397

2024

Engineering aortic valves via transdifferentiating fibroblasts into valvular endothelial cells without using viruses or iPS cells.

Applications

Unspecified application

Species

Unspecified reactive species

Peng Tang,Fuxiang Wei,Weihua Qiao,Xing Chen,Chenyang Ji,Wanzhi Yang,Xinyu Zhang,Sihan Chen,Yanyan Wu,Mingxing Jiang,Chenyu Ma,Weiqiang Shen,Qi Dong,Hong Cao,Minghui Xie,Ziwen Cai,Li Xu,Jiawei Shi,Nianguo Dong,Junwei Chen,Ning Wang

Frontiers in neurology 13:886040 PubMed36003300

2022

Identification of protein biomarkers in host cerebrospinal fluid for differential diagnosis of tuberculous meningitis and other meningitis.

Applications

Unspecified application

Species

Unspecified reactive species

Mailing Huang,Zeyu Ding,Wensheng Li,Weibi Chen,Yadong Du,Hongyan Jia,Qi Sun,Boping Du,Rongrong Wei,Aiying Xing,Qi Li,Naihui Chu,Liping Pan

Scientific reports 11:21852 PubMed34750441

2021

Human endothelial cells and fibroblasts express and produce the coagulation proteins necessary for thrombin generation.

Applications

Unspecified application

Species

Unspecified reactive species

Clay T Cohen,Nancy A Turner,Joel L Moake
제품이 사용된 논문 모두 보기
websiteProtocolBooklet
en

Product promise

저희는 고품질 시약으로 고객님의 연구를 서포트하고자 최선을 다하고 있으며, 모든 단계에서 함께 하겠습니다. 만약 제품이 기대한 성능을 보이지 않을 경우에도 Product Promise로 보호받으실 수 있습니다.
자세한 내용은 이용 약관을 확인해 주세요.

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com