Human CYR61 ELISA Kit, Chemiluminescent
- SimpleStep Ignite™ ELISA
- Recombinant
- 각 태그의 뜻
Be the first to review this product! 리뷰 제출
|
(0 출판물)
- Single 30 min incubation and single-wash step for results in less than an hour.
- Chemiluminescent detection allows a broad dynamic range: 16.46 - 4000 pg/ml with a sensitivity of 5 pg/mL.
- Design your own immunoassay: we also offer the conjugation-ready antibody pair.
- Patent pending
- sELISA
Lab
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Dynamic range comparison between the Chemiluminescent Human CYR61 SimpleStep ELISA and colorimetric Human CYR61 SimpleStep ELISA (ab238267) for 1X Cell Extraction Buffer PTR, and leading colorimetric competitor. The Chemiluminescent SimpleStep ELISA kit shows increased sensitivity and increased dynamic range.
- sELISA
Lab
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Standard curve comparison between the Chemiluminescent Human CYR61 SimpleStep ELISA and colorimetric Human CYR61 SimpleStep ELISA (ab238267) in 1X Cell Extraction Buffer PTR. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Interpolated concentration of native CYR61 was measured in duplicate at different sample concentrations. Undiluted samples are 100% serum, plasma (citrate), and urine. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions for serum and plasma are made in Sample Diluent 25BP, and sample dilutions for urine and made in Sample Diluent NS.
- sELISA
Supplier Data
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Interpolated concentrations of native CYR61 in human HeLa cell extract based on a 250 μg/mL extract load and MDA-MB435S cell extract based on a 500 μg/mL extract load. The concentrations of CYR61 were measured in duplicate and interpolated from the CYR61 standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CYR61 concentration was determined to be 1,097 pg/mL in HeLa cell extract and 1,717 pg/mL in MDA-MB-435S cell extract.
- sELISA
Supplier Data
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Serum from ten individual healthy human female donors was measured in duplicate.
Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CYR61 concentration was determined to be 170.3 pg/mL with a range of 97. 07 – 254.9 pg/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human CYR61 ELISA Kit, Chemiluminescent (AB326749)
Interpolated concentrations of native CYR61 in human breast milk (de-fatted), saliva, and cell culture supernatant (SN) samples.
The concentrations of CYR61 were measured in duplicates, interpolated from the CYR61 standard curves and corrected for sample dilution. Undiluted samples are as follows : milk 100%, saliva 100%, HeLa supernatant 25%, and MDA-MB-453S 25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CYR61 concentration was determined to be 1,432 pg/mL in neat milk, 798.2 pg/mL in neat saliva, 8,357 pg/mL neat HeLa cell culture supernatant, and 1,984 pg/mL in neat MDA-MB-453S cell culture supernatant.
Reactivity 정보
제품 세부 정보
Human CYR61 ELISA Kit, Chemiluminescent (ab326749) is a rapid single-wash sandwich 55-min ELISA to measure Human CYR61 in Cell culture supernatant, Serum, Milk, Cell culture extracts, Urine, Saliva, Tissue Extracts, Citrate plasma with a sensitivity of 5 pg/mL.
How the assay works
Human CYR61 ELISA Kit, Chemiluminescent (ab326749) SimpleStep Ignite™ ELISA employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep Ignite™ ELISA kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human CYR61 (ab326749) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-CCN1 antibody [EPR21133-104] - BSA and Aside free (Capture) ab244801
- Anti-CCN1 antibody [EPR21133-20] - BSA and Aside free (Detector) ab245074
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
제품 구성
특성 및 보관 정보
배송 시 보관 조건
적절한 단기 보관 조건
적절한 장기 보관 조건
보관 정보
타겟 정보
대체 명칭 보기
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com