Human HLA-DR ELISA Kit
- Recombinant
- SimpleStep
- 각 태그의 뜻
Be the first to review this product! 리뷰 제출
|
(1 출판물)
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
- ELISA
Supplier Data
ELISA - Human HLA-DR ELISA Kit (AB223593)
- sELISA
Supplier Data
Sandwich ELISA - Human HLA-DR ELISA Kit (AB223593)
Representative image of Human HLA-DR ELISA Kit (ab223593)
Components shown from left to right :
- 10X Wash Buffer PT (ab206977)
- 10X Human HLA-DR ELISA Kit Capture Antibody
- 10X Human HLA-DR Detector Antibody
- 10X Human HLA-DR ELISA Kit Lyophilised Purified Protein (2 vials)
- Human HLA-DR ELISA Kit 50X Cell Extraction Enhancer Solution (ab193971)
- Sample diluent NS
- TMB solution
- Stop Solution
- 5X Cell Extraction Buffer PTR (ab193970)
- Antibody Diluent 4BI
SimpleStep Pre-Coated 96-Well Microplate (ab206978) - shown behind bottles / vials.
Plate Seals - shown underneath bottles / vials.
Note : The vial labels shown in this image use generic names for illustrative purposes only and may not exactly match the specific component names included in the ELISA kit.
Note : Colors of solutions in image may not precisely match the shade of colors in the actual kit
- sELISA
Supplier Data
Sandwich ELISA - Human HLA-DR ELISA Kit (AB223593)
Interpolated concentrations of native HLA-DR in human cell and tissue extract samples.
The concentrations of HLA-DR were measured in duplicates, interpolated from the HLA-DR standard curves corrected for sample dilution and extract load. Undiluted samples are as follows : Daudi cell extract 32.3 μg/mL, Raji cell extract 490 μg/mL, and human skin extract 500 μg/mL. The interpolated dilution factor and corrected values are plotted (mean +/- SD, n=2). The mean HLA-DR concentration was determined to be 52.0 pg/μg in Daudi Extract, 1.93 pg/μg in Raji Extract and 0.85 pg/μg in human skin homogenate extract.
- sELISA
Supplier Data
Sandwich ELISA - Human HLA-DR ELISA Kit (AB223593)
Example of human HLA-DR standard curve.
Background-subtracted data values (mean +/- SD) are graphed.
Reactivity 정보
제품 세부 정보
Human HLA-DR ELISA Kit ab223593 is a rapid single-wash 90-min Sandwich ELISA to measure Human HLA-DR in cell culture extracts, tissue homogenate. This SimpleStep sensitivity is 5 pg/mL.
How the assay works
Human HLA-DR SimpleStep ELISA®employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details.
Assay Specificity
Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human HLA-DR ELISA Kit ab223593 protocol summary
1. Mix: add samples/standards to the wells together with the capture and detector antibody cocktail. Incubate 1 hr at room temperature
2. Wash
3. Add TMB development solution - incubate for 10 min
4. Add Stop solution
5. Read the results on a plate reader at 450 nm
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-HLA-DR antibody [EPR20209-156] - BSA and Azide free (Capture) ab242928
- Anti-HLA-DR antibody [EPR20209-171] - BSA and Azide free (Detector) ab242928
HLA class II histocompatibility antigen, DR alpha chain (HLA-DR) is the alpha chain of a cell surface receptor heterodimer that binds peptides for presentation to CD4 T cells. The alpha chain is fairly constant between individuals and pairs with varying alleles of the beta chain. HLA-DR has been implicated in multiple auto-immune conditions, as well as graft vs host disease.
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
제품 구성
특성 및 보관 정보
배송 시 보관 조건
적절한 단기 보관 조건
적절한 장기 보관 조건
보관 정보
타겟 정보
대체 명칭 보기
제품이 사용된 논문 (1)
Recent publications for all applications. Explore the 전체 목록 and refine your search
Journal of tissue engineering and regenerative medicine 16:290-296 PubMed34965018
2022
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com