Anti-Bcl10 antibody [EP606Y] - BSA and Azide free
- RabMAb
- Recombinant
- KO Validated
- 각 태그의 뜻
Be the first to review this product! 리뷰 제출
|
(1 출판물)
- ICC/IF
Unknown
Immunocytochemistry/ Immunofluorescence - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Clone EP606Y (ab189219) has been successfully conjugated by Abcam. This image was generated using Anti-Bcl10 antibody [EP606Y] (Alexa Fluor® 488). Please refer to ab200318 for protocol details.
ab200318 staining Bcl-10 in HeLa cells. The cells were fixed with 100% methanol (5min), permeabilized with 0.1% Triton X-100 for 5 minutes and then blocked with 1% BSA/10% normal goat serum/0.3M glycine in 0.1% PBS-Tween for 1h. The cells were then incubated overnight at +4°C with ab200318 at 1/200 dilution (shown in green) and ab195889, Mouse monoclonal to alpha Tubulin (Alexa Fluor® 594), at 2µg/ml (shown in red). Nuclear DNA was labelled with DAPI (shown in blue).
Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8).
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Immunohistochemical staining of paraffin embedded human lung carcinoma tissue with purified ab33905 at a working dilution of 1/50. The secondary antibody used is ab97051, a goat anti-rabbit IgG (H&L) at a dilution of 1/500. The sample is counter-stained with hematoxylin. Antigen retrieval was perfomed using Tris-EDTA buffer, pH 9.0. PBS was used instead of the primary antibody as the negative control, and is shown in the inset.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
- Flow Cyt (Intra)
Unknown
Flow Cytometry (Intracellular) - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Intracellular Flow Cytometry analysis of Raji (human Burkitt's lymphoma) cells labeling Bcl10 (red) with ab33905 at a 1/200 dilution. Cells were fixed with 4% paraformaldehyde and permeabilized with 90% methanol. A goat anti-rabbit IgG (Alexa Fluorr® 488) (ab150077) was used as the secondary antibody at a 1/2000 dilution. Black - Rabbit monoclonal IgG (ab172730). Blue (unlabeled control) - Cells without incubation with primary and secondary antibodies.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
- ICC/IF
Unknown
Immunocytochemistry/ Immunofluorescence - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Immunofluorescence staining of Raji cells with purified ab33905 at a working dilution of 1/100, counter-stained with DAPI. The secondary antibody was Alexa Fluor® 488 goat anti-rabbit (ab150077), used at a dilution of 1/1000. ab7291, a mouse anti-tubulin antibody (1/1000), was used to stain tubulin along with ab150120 (Alexa Fluor® 594 goat anti-mouse, 1/1000), shown in the top right hand panel. The cells were fixed in 4 % PFA and permeabilized using 0.1% Triton X 100. The negative controls are shown in bottom middle and right hand panels - for negative control 1, purified ab33905 was used at a dilution of 1/500 followed by an Alexa Fluor® 594 goat anti-mouse antibody (ab150120) at a dilution of 1/500. For negative control 2, ab7291 (mouse anti-tubulin) was used at a dilution of 1/500 followed by an Alexa Fluor® 488 goat anti-rabbit antibody (ab150077) at a dilution of 1/400.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Unpurified ab33905, at a 1/100 dilution, staining human hepatocellular carcinoma by Immunohistochemistry, Paraffin embedded tissue.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
- ICC/IF
Unknown
Immunocytochemistry/ Immunofluorescence - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
Unpurified ab33905, staining HeLa cells by Immunofluorescent.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
- IP
Unknown
Immunoprecipitation - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
ab33905 (purified) at 1/20 immunoprecipitating Bcl10 in 10 μg Ramos cell lysate (Lanes 1 and 2, observed at 32 kDa). Lane 3 - Rabbit monoclonal IgG (ab172730). For western blotting, VeriBlot for IP Detection Reagent (HRP) (ab131366), was used for detection at 1/10,000 dilution. Blocking buffer and concentration : 5% NFDM/TBST Dilution buffer and concentration : 5% NFDM/TBST
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab33905).
All lanes:
Immunoprecipitation - Anti-Bcl10 antibody [EP606Y] (<a href='/ko/products/primary-antibodies/bcl10-antibody-ep606y-ab33905'>ab33905</a>)
Predicted band size: 26 kDa
false
- WB
Lab
Western blot - Anti-Bcl10 antibody [EP606Y] - BSA and Azide free (AB189219)
This data was developed using the same antibody clone in a different buffer formulation (ab33905).
Lanes 1-4 : Merged signal (red and green). Green - ab33905 observed at 32 kDa. Red - loading control, ab7291 observed at 52 kDa.
ab33905 Anti-Bcl10 antibody [EP606Y] was shown to specifically react with Bcl10 in wild-type HeLa cells. Loss of signal was observed when knockout cell line ab261797 (knockout cell lysate ab257144) was used. Wild-type and Bcl10 knockout samples were subjected to SDS-PAGE. ab33905 and Anti-alpha Tubulin antibody [DM1A] - Loading Control (ab7291) were incubated overnight at 4°C at 1 in 1000 dilution and 1 in 20000 dilution respectively. Blots were developed with Goat anti-Rabbit IgG H&L (IRDye® 800CW) preadsorbed (ab216773) and Goat anti-Mouse IgG H&L (IRDye® 680RD) preadsorbed (ab216776) secondary antibodies at 1 in 10000 dilution for 1 hour at room temperature before imaging.
All lanes:
Western blot - Anti-Bcl10 antibody [EP606Y] (<a href='/ko/products/primary-antibodies/bcl10-antibody-ep606y-ab33905'>ab33905</a>) at 1/1000 dilution
Lane 1:
Wild-type HeLa cell lysate at 20 µg
Lane 2:
BCL10 knockout HeLa cell lysate at 20 µg
Lane 3:
Ramos cell lysate at 20 µg
Lane 4:
A549 cell lysate at 20 µg
Predicted band size: 26 kDa
Observed band size: 32 kDa
false
관련 conjugated 항체와 다양한 조성의 항체 (10)
-
Anti-Bcl10 antibody [EP606Y]
-
660 APC
APC Anti-Bcl10 antibody [EP606Y]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Bcl10 antibody [EP606Y]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-Bcl10 antibody [EP606Y]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-Bcl10 antibody [EP606Y]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-Bcl10 antibody [EP606Y]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Bcl10 antibody [EP606Y]
-
775 Alexa Fluor® 750
Alexa Fluor® 750 Anti-Bcl10 antibody [EP606Y]
-
HRP Anti-Bcl10 antibody [EP606Y]
-
578 PE
PE Anti-Bcl10 antibody [EP606Y]
Reactivity 정보
제품 세부 정보
ab189219 is the carrier-free version of ab33905.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Species reactivity
Rat: We have preliminary internal testing data to indicate this antibody may not react with this species.
Please contact us for more information.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
특성 및 보관 정보
제형
Purification 테크닉
보관 버퍼
배송 시 보관 조건
적절한 단기 보관 조건
적절한 장기 보관 조건
보관 정보
추가 정보
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
Bcl10 activates downstream signaling pathways that are critical for immune cell functioning and survival. It forms part of the CARD-BCL10-MALT1 (CBM) complex which is important for the activation of the NF-kB pathway. This complex formation is essential for lymphocyte activation and proliferation. Bcl10 interactions within this complex influence cellular responses to various stimuli helping organisms to mount appropriate immune responses.
Pathways
Bcl10 serves as an integral component in the NF-kB and TCR signaling pathways. It functions alongside proteins such as MALT1 and CARD9 in these pathways. The proper functioning of Bcl10 in these pathways ensures accurate transcriptional regulation necessary for immune responses. Misregulation in these pathways can lead to immune disorders and aberrant cell behavior linking Bcl10 to further biological implications.
제품 프로토콜
- Visit the General protocols
- Visit the Troubleshooting
타겟 정보
대체 명칭 보기
제품이 사용된 논문 (1)
Recent publications for all applications. Explore the 전체 목록 and refine your search
Alzheimer's research & therapy 17:81 PubMed40229846
2025
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com