- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Glucagon [EP3070] – Mouse IgG1 (Chimeric) (AB322273)
Immunofluorescence staining of glucagon in sections of formalin-fixed paraffin-embedded human pancreas (positive) and cerebellum (negative)*. Performed on a Leica BOND. The section was pre-treated using heat mediated antigen retrieval with sodium citrate (pH6.0) for 20 minutes. The section was then incubated at room temperature for 1 hour with ab322273 at 1/500 dilution and then incubated for 1 hour with ab150117 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 dilution (shown in green). Nuclear DNA was labelled with DAPI (shown in blue). The section was then mounted using Dako Fluorescence Mounting Medium®. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). For other IHC staining systems (automated and non-automated), customers should optimize variable parameters such as antigen retrieval conditions, antibody concentrations and incubation times. *Tissue obtained from the Human Research Tissue Bank, supported by the NIHR Cambridge Biomedical Research Centre.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Glucagon [EP3070] – Mouse IgG1 (Chimeric) (AB322273)
Immunofluorescence staining of glucagon in sections of formalin-fixed paraffin-embedded rat pancreas (positive) and brain (negative)*. Performed on a Leica BOND. The section was pre-treated using heat mediated antigen retrieval with sodium citrate (pH6.0) for 20 minutes. The section was then incubated at room temperature for 1 hour with ab322273 at 1/100 dilution and then incubated for 1 hour with ab150117 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 dilution (shown in green). Nuclear DNA was labelled with DAPI (shown in blue). The section was then mounted using Dako Fluorescence Mounting Medium®. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). For other IHC staining systems (automated and non-automated), customers should optimize variable parameters such as antigen retrieval conditions, antibody concentrations and incubation times.
관련 conjugated 항체와 다양한 조성의 항체 (7)
-
Anti-Glucagon antibody [EP3070]
-
Anti-Glucagon antibody [EP3070] - BSA and Azide free
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Glucagon antibody [EP3070]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-Glucagon antibody [EP3070]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-Glucagon antibody [EP3070]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Glucagon antibody [EP3070]
-
Biotin Anti-Glucagon antibody [EP3070]
Reactivity 정보
제품 세부 정보
This mouse monoclonal chimeric antibody has been engineered from a RabMAb parent antibody (ab92517). By necessity, some rabbit sequence is retained as part of the variable domain. When multiplexing with other rabbit-derived antibodies, using cross absorbed Fc-reactive secondary antibodies are recommended.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
특성 및 보관 정보
제형
Purification 테크닉
보관 버퍼
배송 시 보관 조건
적절한 단기 보관 기간
적절한 단기 보관 조건
적절한 장기 보관 조건
제품 프로토콜
- Visit the General protocols
- Visit the Troubleshooting
타겟 정보
대체 명칭 보기
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com