Anti-HRG antibody [EPR24184-52]
- BOND RX™ Validated
- 20ul selling size
- RabMAb
- Recombinant
- 각 태그의 뜻
Be the first to review this product! 리뷰 제출
|
(0 출판물)
Rabbit Recombinant Monoclonal HRG antibody. Suitable for IHC-P, IP, WB and reacts with Human samples.
대체 명칭 보기
Histidine-rich glycoprotein, Histidine-proline-rich glycoprotein, HPRG, HRG
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRG antibody [EPR24184-52] (AB281563)
Immunohistochemical analysis of paraffin-embedded Human tonsil tissue labeling HRG with ab281563 at 1/5000 dilution, followed by ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Negative control : no staining on human tonsil. The section was incubated with ab281563 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counter stained with Hematoxylin.
Secondary antibody only control : Ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRG antibody [EPR24184-52] (AB281563)
Immunohistochemical analysis of paraffin-embedded Human colon tissue labeling HRG with ab281563 at 1/5000 dilution, followed by ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on the plasma and stroma cells in human colon (PMID : 25243896) is observed. The section was incubated with ab281563 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counter stained with Hematoxylin.
Secondary antibody only control : Ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRG antibody [EPR24184-52] (AB281563)
Immunohistochemical analysis of paraffin-embedded Human pancreas tissue labeling HRG with ab281563 at 1/5000 dilution, followed by ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Negative control : no staining on human pancreas. The section was incubated with ab281563 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counter stained with Hematoxylin.
Secondary antibody only control : Ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRG antibody [EPR24184-52] (AB281563)
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling HRG with ab281563 at 1/5000 dilution, followed by ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human liver. (PMID : 21215706) is observed. The section was incubated with ab281563 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counter stained with Hematoxylin.
Secondary antibody only control : Ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IP
Supplier Data
Immunoprecipitation - Anti-HRG antibody [EPR24184-52] (AB281563)
HRG was immunoprecipitated from 0.35 mg of Human liver tissue lysate with ab281563 at 1/30 dilution (2μg in 0.35mg lysates). Western blot was performed from the immunoprecipitate using ab281563 at 1/1000 dilution. VeriBlot for IP secondary antibody(HRP)(ab131366), was used as secondary antibody at 1/5000 dilution.
Lane 1 : Human liver tissue lysate 10μg (Input).
Lane 2 : ab281563 IP in Human liver tissue lysate.
Lane 3 : Rabbit monoclonal IgG (ab172730) instead of ab281563 in Human liver tissue lysate.
Blocking and dilution buffer and concentration : 5% NFDM/TBST.
Exposure time : 15 seconds.
All lanes:
Immunoprecipitation - Anti-HRG antibody [EPR24184-52] (ab281563)
Predicted band size: 60 kDa
false
- WB
Supplier Data
Western blot - Anti-HRG antibody [EPR24184-52] (AB281563)
The MW and expression pattern is consistent to previous referecence (PMID : 14744774, PMID : 25363753, PMID : 19712047)
Low expression or negative : human pancreas (PMID : 25363753)
Blocking and dilution buffer and concentration : 5% NFDM/TBST.
Exposure time : Lane 1 : 3.25 seconds;
Lane 2-3 : 3 minutes.
All lanes:
Western blot - Anti-HRG antibody [EPR24184-52] (ab281563) at 1/1000 dilution
Lane 1:
Human plasma at 20 µL
Lane 2:
Human liver tissue lysate at 20 µg
Lane 3:
Human pancreas tissue lysate at 20 µg
Secondary
Lane 1:
Goat Anti-Rabbit IgG (HRP) with minimal cross-reactivity with human IgG at 1/2000 dilution
Lanes 2 - 3:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/ko/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/100000 dilution
Predicted band size: 60 kDa
false
관련 conjugated 항체와 다양한 조성의 항체 (1)
-
Anti-HRG antibody [EPR24184-52] - BSA and Azide free
Reactivity 정보
제품 세부 정보
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
특성 및 보관 정보
제형
Purification 테크닉
보관 버퍼
배송 시 보관 조건
적절한 단기 보관 기간
적절한 단기 보관 조건
적절한 장기 보관 조건
분주 정보
보관 정보
제품 프로토콜
- Visit the General protocols
- Visit the Troubleshooting
타겟 정보
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com