Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51]
- 20ul selling size
- BOND RX™ Validated
- Advanced Validation
- RabMAb
- Recombinant
- 각 태그의 뜻
Be the first to review this product! 리뷰 제출
|
(0 출판물)
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Human stomach tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human stomach.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Negative control : no staining on human liver.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Human colon tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human colon (PMID : 36612049).
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Mouse colon tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on mouse colon.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Mouse stomach tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on mouse stomach.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Rat colon tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on rat colon (PMID : 8282777).
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Rat stomach tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on rat stomach.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Mouse cerebrum tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Negative control : no staining on mouse cerebrum.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- mIHC
Lab
Multiplex immunohistochemistry - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemistry analysis of Formalin/PFA-fixed paraffin-embedded sections mouse stomach tissue labelling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 dilution (B), CD34 with ab316277 at 1/10000 dilution (C) and Cathepsin E with ab322657 at 1/5000 dilution (D). Opal Polymer HRP Ms + Rb was used as a secondary antibody, and DAPI was used for a nuclear counter stain. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
Panel A : merged staining of anti-Sodium/Hydrogen Exchanger 1/NHE-1 (magenta; Opal™690), anti-CD34 (green; Opal™520) and anti-Cathepsin E (gray; Opal™570) on mouse stomach.
Panel B : anti-Sodium/Hydrogen Exchanger 1/NHE-1 showed membranous staining in epithelium of mouse stomach.
Panel C : anti-CD34 staining endothelium in mouse stomach.
Panel D : anti-Cathepsin E showed cytoplasmic staining in mouse stomach.
Nuclear DNA was labeled with DAPI (shown in blue).
The section was incubated in three rounds of staining : in the order of ab322349, ab316277 and ab322657 for 30 mins at room temperature. Each round was followed by a separate fluorescent tyramide signal amplification system.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument with an Opal™ 4-color kit. Image acquisition was performed with Leica SP8 confocal microscope.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Mouse liver tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Negative control : no staining on mouse liver.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] (AB322349)
Immunohistochemical analysis of paraffin-embedded Rat liver tissue labeling Sodium/Hydrogen Exchanger 1/NHE-1 with ab322349 at 1/4000 (0.125 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Negative control : no staining on rat liver.
The section was incubated with ab322349 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Slides were incubated with 3% Hydrogen Peroxide for 10 mins at room temperature after secondary antibody incubation to reduce the background
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
관련 conjugated 항체와 다양한 조성의 항체 (4)
-
Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51] - BSA and Azide free
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Sodium/Hydrogen Exchanger 1/NHE-1 antibody [EPR28913-51]
Reactivity 정보
제품 세부 정보
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
특성 및 보관 정보
제형
Purification 테크닉
보관 버퍼
배송 시 보관 조건
적절한 단기 보관 기간
적절한 단기 보관 조건
적절한 장기 보관 조건
분주 정보
보관 정보
제품 프로토콜
- Visit the General protocols
- Visit the Troubleshooting
타겟 정보
대체 명칭 보기
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com