Overview

  • Product name

    Mouse CXCL11 Antibody Pair - BSA and Azide free
    See all CXCL11 kits
  • Detection method

    Colorimetric
  • Assay type

    ELISA set
  • Range

    62.5 pg/ml - 4000 pg/ml
  • Species reactivity

    Reacts with: Mouse
  • Product overview

    The Antibody Pair can be used to quantify Mouse CXCL11. BSA and Azide free antibody pairs include unconjugated capture and detector antibodies suitable for sandwich ELISAs. The antibodies are provided at an approximate concentration of 1 mg/ml as measured by the protein A280 method. The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Both capture and detector antibodies are rabbit monoclonal antibodies delivering consistent, specific, and sensitive results.


    For additional information on the performance of the antibody pair, see the equivalent SimpleStep ELISA® Kit (ab204519), which uses the same antibodies. Please note that the range provided for the pairs is only an estimation based on the performance of the related product using the same antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody pair in your assay.


    To receive an electronic copy of the Certificate of Analysis, please send an email to technical support with "CoA for matched antibody pair kit" in the subject line and the desired product number and lot number in the body of the email.


    Download SDS here.


     

  • Tested applications

    Suitable for: ELISAmore details
  • Platform

    Reagents

Properties

  • Storage instructions

    Store at +4°C. Please refer to protocols.
  • Components 10 x 96 tests
    Mouse CXCL11 Capture Antibody 1 x 100µg
    Mouse CXCL11 Detector Antibody 1 x 100µg
  • Research areas

  • Function

    Chemotactic for interleukin-activated T-cells but not unstimulated T-cells, neutrophils or monocytes. Induces calcium release in activated T-cells. Binds to CXCR3. May play an important role in CNS diseases which involve T-cell recruitment. May play a role in skin immune responses.
  • Tissue specificity

    High levels in peripheral blood leukocytes, pancreas and liver astrocytes. Moderate levels in thymus, spleen and lung. Low levels in placenta, prostate and small intestine. Also found in epidermal basal layer keratinocytes in skin disorders.
  • Sequence similarities

    Belongs to the intercrine alpha (chemokine CxC) family.
  • Cellular localization

    Secreted.
  • Information by UniProt
  • Alternative names

    • b R1
    • b-R1
    • Beta-R1
    • betaR1
    • C-X-C motif chemokine 11
    • Chemokine (C-X-C motif) ligand 11
    • Chemokine C-X-C motif ligand 11
    • CXC11
    • CXCL11
    • CXL11_HUMAN
    • H174
    • I TAC
    • I-TAC
    • Interferon gamma inducible protein 9
    • Interferon gamma-inducible protein 9
    • Interferon inducible T cell alpha chemoattractant
    • Interferon-inducible T-cell a chemoattractant I-TAC
    • Interferon-inducible T-cell alpha chemoattractant
    • IP 9
    • IP-9
    • IP9
    • ITAC
    • MGC102770
    • SCYB11
    • SCYB9B
    • Small inducible cytokine B11
    • Small inducible cytokine subfamily B (Cys-X-Cys) member 11
    • Small inducible cytokine subfamily B (Cys-X-Cys) member 9B
    • Small inducible cytokine subfamily B, member 11
    • Small inducible cytokine subfamily B, member 9B
    • Small-inducible cytokine B11
    see all
  • Database links

Associated products

Applications

Our Abpromise guarantee covers the use of ab241721 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
ELISA Use at an assay dependent concentration.

References

ab241721 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

There are currently no Customer reviews or Questions for ab241721.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Sign up