Overview

  • Product name

    Mouse PAI Matched Antibody Pair Kit
    See all PAI1 kits
  • Detection method

    Colorimetric
  • Assay type

    ELISA set
  • Range

    125 pg/ml - 8000 pg/ml
  • Species reactivity

    Reacts with: Mouse
  • Product overview

    Matched Antibody Pair Kits include a capture and a biotinylated detector antibody pair, along with a calibrated protein standard, suitable for sandwich ELISA. The Matched Antibody Pair Kit can be used to quantify native and recombinant mouse PAI 1.


    Matched antibody pair kits and reagents deliver consistent, specific, and sensitive results.



    • Batch-to-batch consistency: only recombinant monoclonal antibodies are used in our matched antibody pairs.

    • Specificity: antibody pairs are screened in plasma and serum to ensure specificity in complex samples.

    • Sensitivity: benchmarked against commercially available antibody pairs to ensure equivalent or superior performance compared with the competition.


     


    Additional buffers and plates are required for the assay. An accessory pack can be purchased which includes buffer reagents required to perform 10 x 96-well plate sandwich ELISAs (ab210905).


     


    For additional information on the performance of the antibody pair used in this kit, please see our equivalent SimpleStep ELISA® (ab197752) which uses the same antibody pair.


     


    To receive an electronic copy of the Certificate of Analysis, please send an email with "CoA for matched antibody pair kit" in the subject line and the desired product number and lot number in the body of the email.


     

  • Tested applications

    Suitable for: ELISAmore details
  • Platform

    Reagents

Properties

  • Storage instructions

    Store at -20°C. Please refer to protocols.
  • Components 10 x 96 tests 2 x 96 tests
    Mouse PAI Capture Antibody 1 x 100µg 1 x 20µg
    Mouse PAI Detector Antibody 1 x 25µg 1 x 5µg
    Mouse PAI Lyophilized Protein 1 vial 1 vial
  • Research areas

  • Function

    This inhibitor acts as 'bait' for tissue plasminogen activator, urokinase, and protein C. Its rapid interaction with TPA may function as a major control point in the regulation of fibrinolysis.
  • Tissue specificity

    Found in plasma and platelets and in endothelial, hepatoma and fibrosarcoma cells.
  • Involvement in disease

    Defects in SERPINE1 are the cause of plasminogen activator inhibitor-1 deficiency (PAI-1D) [MIM:613329]. It is a hematologic disorder characterized by increased bleeding after trauma, injury, or surgery. Affected females have menorrhagia. The bleeding defect is due to increased fibrinolysis of fibrin blood clots due to deficiency of plasminogen activator inhibitor-1, which inhibits tissue and urinary activators of plasminogen.
    Note=High concentrations of SERPINE1 seem to contribute to the development of venous but not arterial occlusions.
  • Sequence similarities

    Belongs to the serpin family.
  • Post-translational
    modifications

    Inactivated by proteolytic attack of the urokinase-type (u-PA) and the tissue-type (TPA), cleaving the 369-Arg-
    -Met-370 bond.
  • Cellular localization

    Secreted.
  • Information by UniProt
  • Alternative names

    • Clade E
    • Endothelial plasminogen activator inhibitor
    • Nexin
    • Nexin plasminogen activator inhibitor type 1
    • PAI
    • PAI 1
    • PAI-1
    • PAI1_HUMAN
    • PLANH1
    • Plasminogen activator inhibitor 1
    • Plasminogen activator inhibitor type 1
    • Serine (or cysteine) proteinase inhibitor
    • Serine (or cysteine) proteinase inhibitor clade E (nexin plasminogen activator inhibitor type 1) member 1
    • Serine proteinase inhibitor clade E member 1
    • serpin
    • Serpin E1
    • Serpin peptidase inhibitor clade E
    • Serpin peptidase inhibitor clade E (nexin plasminogen activator inhibitor type 1) member 1
    • Serpine 1
    • SERPINE1
    see all
  • Database links

Applications

Our Abpromise guarantee covers the use of ab221436 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
ELISA Use at an assay dependent concentration.

Images

  • Standard calibration curve. Background subtracted values are graphed.

Protocols

References

ab221436 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

There are currently no Customer reviews or Questions for ab221436.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Sign up