For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

We use cookies to make our site as useful as possible.

Our Cookie Policy explains how you can opt-out of the cookies we use.

If you continue without changing your cookie settings, we'll assume you’re happy with this.

Continue Continue

United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Diagnostic & Therapeutic Solutions
    Custom solutions & partnerships

    Custom antibody development and commercial partnerships to advance your diagnostic and therapeutic discovery.

    Create custom solutions with us

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

Supporting our customers and employees during the COVID-19 pandemic. Read more

  1. Link

    pe-cd5-antibody-cris1-ab1157.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Immunology Adaptive Immunity B Cells CD
Share by email

PE Anti-CD5 antibody [CRIS1] (ab1157)

  • Datasheet
  • SDS
Submit a review Q&A (3)References (1)

Product price, shipping and contact information

Currently unavailable

Sorry, we can't display this right now.

Please contact us to place your order, or try again later.

 

Loading size & price…

 

Shipping and order information

Abpromise

Guaranteed product quality, expert customer support.

Find out more.

Key features and details

  • PE Mouse monoclonal [CRIS1] to CD5
  • Reacts with: Human
  • Conjugation: PE. Ex: 488nm, Em: 575nm
  • Isotype: IgG2a

You may also be interested in

Primary
Product image
Anti-CD5 antibody [EP2952] - BSA and Azide free (ab194821)
Primary
Product image
Anti-Prion protein PrP antibody (ab703)

View more associated products

Overview

  • Product name

    PE Anti-CD5 antibody [CRIS1]
    See all CD5 primary antibodies
  • Description

    PE Mouse monoclonal [CRIS1] to CD5
  • Host species

    Mouse
  • Conjugation

    PE. Ex: 488nm, Em: 575nm
  • Species reactivity

    Reacts with: Human
  • General notes

    Reproducibility is key to advancing scientific discovery and accelerating scientists’ next breakthrough.

    Abcam is leading the way with our range of recombinant antibodies, knockout-validated antibodies and knockout cell lines, all of which support improved reproducibility.

    We are also planning to innovate the way in which we present recommended applications and species on our product datasheets, so that only applications & species that have been tested in our own labs, our suppliers or by selected trusted collaborators are covered by our Abpromise™ guarantee.

    In preparation for this, we have started to update the applications & species that this product is Abpromise guaranteed for.

    We are also updating the applications & species that this product has been “predicted to work with,” however this information is not covered by our Abpromise guarantee.

    Applications & species from publications and Abreviews that have not been tested in our own labs or in those of our suppliers are not covered by the Abpromise guarantee.

    Please check that this product meets your needs before purchasing. If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, as well as customer reviews and Q&As.

Properties

  • Form

    Liquid
  • Storage instructions

    Shipped at 4°C. Store at +4°C.
  • Storage buffer

    Preservative: 0.1% Sodium azide
    Constituent: 0.5% BSA
  • Concentration information loading...
  • Clonality

    Monoclonal
  • Clone number

    CRIS1
  • Myeloma

    unknown
  • Isotype

    IgG2a
  • Light chain type

    unknown
  • Research areas

    • Immunology
    • Adaptive Immunity
    • B Cells
    • CD
    • Immunology
    • Adaptive Immunity
    • T Cells
    • CD
    • Stem Cells
    • Hematopoietic Progenitors
    • Lymphoid
    • B Lymphocytic Lineage
    • Stem Cells
    • Hematopoietic Progenitors
    • Lymphoid
    • T Lymphocytic Lineage

Associated products

  • Alternative Versions

    • FITC Anti-CD5 antibody [CRIS1] (ab1156)
  • Isotype control

    • PE Mouse IgG2a [X5563] - Isotype Control (ab91363)
  • Recombinant Protein

    • Recombinant Human CD5 protein (denatured) (ab180322)

Target

  • Function

    May act as a receptor in regulating T-cell proliferation. CD5 interacts with CD72/LYB-2.
  • Sequence similarities

    Contains 3 SRCR domains.
  • Cellular localization

    Membrane.
  • Target information above from: UniProt accession P06127 The UniProt Consortium
    The Universal Protein Resource (UniProt) in 2010
    Nucleic Acids Res. 38:D142-D148 (2010) .

    Information by UniProt
  • Database links

    • Entrez Gene: 921 Human
    • Omim: 153340 Human
    • SwissProt: P06127 Human
    • Unigene: 58685 Human
    • Alternative names

      • CD 5 antibody
      • CD5 antibody
      • CD5 antigen (p56 62) antibody
      • CD5 antigen antibody
      • CD5 molecule antibody
      • CD5_HUMAN antibody
      • LEU1 antibody
      • LyA antibody
      • Lymphocyte antigen T1/Leu-1 antibody
      • OTTHUMP00000236973 antibody
      • T-cell surface glycoprotein CD5 antibody
      • T1 antibody
      see all

    Protocols

    • Flow cytometry protocols

    Click here to view the general protocols

    Datasheets and documents

    • Datasheet
    • SDS
  • References (1)

    Publishing research using ab1157? Please let us know so that we can cite the reference in this datasheet.

    ab1157 has been referenced in 1 publication.

    • Bernard A & Boumsell L The clusters of differentiation (CD) defined by the First International Workshop on Human Leucocyte Differentiation Antigens. Hum Immunol 11:1-10 (1984). PubMed: 6434495

    Customer reviews and Q&As

    Show All Reviews Q&A
    Submit a review Submit a question

    1-3 of 3 Abreviews or Q&A

    Question

    The gels that we have been using are non-reducing, non-denaturing. The amount of protein loaded vary according to our daily plans.... but should be more than sufficient in order to detect bands. We haven't used loading controls at this point... we wanted to see something first. We used the NP-40 buffer documented in your western blot beginners pdf file. In the case of all the antibodies ordered, they have been designated by Abcam as tested for Western blots. Do you have any images on files that I can take a look at? What type of tissue did you use for the testing? How different was your protocol from the one established in our lab? Sorry for all the questions but maybe I can use this info for some of the trouble shooting on our end.

    Read More

    Abcam community

    Verified customer

    Asked on Jul 25 2006

    Answer

    Thank you for your enquiry. I appreciate your continued patience in this matter. I have received some feedback from some of the sources of the antibodies that you are enquiring about; ab7033 - To follow on with the comments that I have made the source of mouse monoclonal [MMP2/2C1] to MMP2 (ab7033) was also concerned with regards the approach that you have used for your sample preparation. I appreciate that you have been using an NP40 buffer extraction. However, this is an approach designed for a cytoplasmic preparation of cell culture cells. I would like to follow up my previous email by recommending that you perform a loading control experiment using an antibody that targets a "housekeeping protein" for example GAPDH or beta actin. This can be performed under the conditions best recognized by the antibody you are using; most likely denaturing, reduced. This will enable you to fully determine the integrity of your protein with respect to its protein composition. My biggest concern with the blot images that you have provided me with are the band doublet that you have been detecting either side of the 37KDa marker as this is present in the majority of your blot images. The source of ab6586 - Collagen IV antibody (ab6586) makes a similar suggestion although Collagens should in fact be electrophoresed as you have been using non-denaturing, non-reduced conditions. However, it is important that the integrity of your samples are confirmed. I am still awaiting further information and am in the process of requesting blot images for the antibodies that you have enquired about. I appreciate your continued patience. I hope this information helps, please do not hesitate to contact us if you need any more advice or information.

    Read More

    Abcam Scientific Support

    Answered on Aug 01 2006

    Question

    Hi again. I submitted the form for ab 2500 (Laminin), however, I am having difficulty re-accessing the questionnaire for the remaining antibodies. For this reason, I will provide the necessary information in this email. I have not been satisfied with the following antibodies: ab11572, EMMPRIN: (bands not at proper place, band at approx. 37 kDa): I have already submitted images of this. ab7033, MMP2: (bands not at proper place, bands below 40 kDa): I have already submitted images of this. ab6586, Collagen IV: (no bands): I have already submitted images of this. 2 hours transfer period. Questions regarding: ab3644, MT1-MMP: bands appear at 50 kDa and approximately 40 kDa. MW should be 66 and 54 kDa. What were your results? Images previously sent. ab1828, TIMP2: bands appear at 25 and 37 kDa. Band is documented to appear at 21 kDa. What are your experiences with this? Images previously sent. For all antibodies: Please find protocol attached to this email. Gels used: Criterion precast (Biorad), non-reducing, percentage determined according to molecular weight investigated All buffers and secondary antibodies used were suggested by Abcam on the data sheets. All protocols included preliminary testing in either 3% skim milk and 3% BSA. If there is anymore information that I may supply, please do not hesitate to contact me. Best regards,

    Read More

    Abcam community

    Verified customer

    Asked on Jul 20 2006

    Answer

    Thank you for your enquiry. Once again I am sorry to hear of the difficulties that you have experienced using these antibodies. I have had a look through the information that you have provided in conjunction with the blot images and I have a few comments. Firstly I am concerned about the sample preparation that has been performed. Many of the extraneous bands that have been detected are significantly lower than I would expect. Curiously many are also doublets at approximately 25KDa and 37KDa. My suspicion would be non-specific labeling possibly due to protein degradation. You have highlighted that the samples were prepared as recommended by Abcam. Please can you detail exactly how this was performed as we make many recommendations for sample preparation. My concern with respect to the sample preparation is that many of the proteins that your are targeting are secreted proteins and therefore require delicate sample preparation. Can you tell me whether the skeletal muscle samples were postmortum, biopsies, surgical specimens etc. I would also appreciate details of the gel conditions that you are using. Similar to my previous response with respect to ab2500 I would appreciate it if you could provide me with details of the gel conditions. I would like to know whether these pre-cast gels are non-denaturing in addition to non-reduced. I would also like details of how the samples are prepared immediately prior to loading on the gel. Can you also provide me with details of the primary and secondary antibody dilutions that have been attempted for each of the samples. Given the non-specific reactivity that you have observed I am also interested whether any no-antibody control experiments have been performed to determine whether the extraneous bands are attricubatble to this reactivity. I additionally have a few comments with respect to individual antibodies that you have been applying: In the experiments that have been performed using ab1828, the secondary that has been employed is ab6721. This is an antibody that is specific for use by IHC and has not been tested for use in western blotting. We have received some excellent feedback as to the application of ab3644 through our Abreviews system. I would like to highlight the importance of a a suitable positive control. For MT1-MMP/MMP14 we recommend the use of placental or breast/lung tissue. For Collagen IV we recommend the use of human epidermal keratinocytes. I look forward to your comments on these matters.

    Read More

    Abcam Scientific Support

    Answered on Jul 21 2006

    Question

    Please find attached images/comments about our optimization for western blots using your products. We have not been able to produce satisfactory results with the following antibodies: ab2500, ab6586, ab7033, ab1157 We also have questions pertaining to the following antibodies: ab1828, ab3644. We are happy to receive advice from past experiences that Abcam may have had in the process of testing these antibodies and are open to continuing the optimization process. However, if satisfactory results are not obtained, we will count on the Abcam product guarantee.

    Read More

    Abcam community

    Verified customer

    Asked on Jun 22 2006

    Answer

    Thank you for your enquiry. I am sorry to hear that you have been having difficulties with these antibodies. The results that you have been obtaining are certainly troubling. What concerns me the most are the two bands that you are consistently detecting at approximately 25 and 37KDa. You are consistently detecing cross reacting bands and never detecting the endogenous target. Whilst some of the antibodies that you detail have not been tested using rat samples; potentially explaining the absence of reactivity with the endogenous band the presence of the two bands at the aforementioned molecular weight accross many of your samples seems to suggest problems with the secondary antibody. Especially in view of the fact that you have changed this antibody and are in fact using three independent secondary antibodies: Goat polyclonal to Rabbit IgG H&L (HRP) (ab6721) Goat polyclonal to Rabbit IgG + Mouse IgG & IgM - prediluted (HRP polymer) (ab2891) Rabbit polyclonal to Goat IgG H&L (HRP) (ab6741) I would appreciate it if you could provide me with protocol details of the approach that you are using so that I can better determine potential reasons for these reacting bands. We have not observed such reactivity with any of the antibodies you list. I am particularly interested in the generic protocol that you have been applying. To provide me with these details please click on the link below and complete our on line technical questionaire. If you have modified the protocol for any of the antibodies at any point please mention this. I am also very interested in the method of sample preparation and the control antibody (loading control) that you have used. https://www.abcam.com/index.html?section=western&pageconfig=technical&intAbID=2500&mode=questionaire I look forward to hearing from you.

    Read More

    Abcam Scientific Support

    Answered on Jun 28 2006

    Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
    For licensing inquiries, please contact partnerships@abcam.com

    Get resources and offers direct to your inbox Sign up
    A-Z by research area
    • Cancer
    • Cardiovascular
    • Cell biology
    • Developmental biology
    • Epigenetics & Nuclear signaling
    • Immunology
    • Metabolism
    • Microbiology
    • Neuroscience
    • Signal transduction
    • Stem cells
    A-Z by product type
    • Primary antibodies
    • Secondary antibodies
    • Biochemicals
    • Isotype controls
    • Flow cytometry multi-color selector
    • Kits
    • Loading controls
    • Lysates
    • Peptides
    • Proteins
    • Slides
    • Tags and cell markers
    • Tools & Reagents
    Help & support
    • Support
    • Make an Inquiry
    • Protocols & troubleshooting
    • Placing an order
    • RabMAb products
    • Biochemical product FAQs
    • Training
    • Browse by Target
    Company
    • Corporate site
    • Investor relations
    • Company news
    • Careers
    • About us
    • Blog
    Events
    • Tradeshows
    • Conferences
    International websites
    • abcam.cn
    • abcam.co.jp

    Join with us

    • LinkedIn
    • facebook
    • Twitter
    • YouTube
    • Terms of sale
    • Website terms of use
    • Cookie policy
    • Privacy policy
    • Legal
    • Modern slavery statement
    © 1998-2021 Abcam plc. All rights reserved.