For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Customized Products & Partnerships
    Customized Products & Partnerships

    Customized products and commercial partnerships to accelerate your diagnostic and therapeutic programs.

    Customized products

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

  1. Link

    products/assay-kits/ammonia-assay-kit-ab83360.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Kits/ Lysates/ Other Kits Cell Metabolism Kits Amino Acid Assays
Share by email

Ammonia Assay Kit (ab83360)

  • Datasheet
  • SDS
  • Protocol Booklet
Reviews (2)Q&A (10)References (38)

Product price, shipping and contact information

Currently unavailable

Sorry, we can't display this right now.

Please contact us to place your order, or try again later.

 

Loading size & price…

 

Shipping and order information

Shipping info

Promotion Information

Abpromise

Guaranteed product quality, expert customer support.

Find out more.

Ammonia Assay Kit ab83360 used with cell culture media
  • Ammonia Assay Kit ab83360 used with liver tissue
  • Ammonia Assay Kit ab83360 used with cell culture media
  • Ammonia Assay Kit ab83360 used with tissue lysates
  • Ammonia Assay Kit ab83360 used with lysates of cultured cells
  • Ammonia Assay Kit ab83360 used with biofluid samples
  • Ammonia assay standard curve

Key features and details

  • Assay type: Quantitative
  • Detection method: Colorimetric
  • Platform: Microplate reader
  • Assay time: 1 hr
  • Sample type: Cell culture media, Cell Lysate, Other biological fluids, Plasma, Serum, Tissue Extracts, Urine
  • Sensitivity: 20 µM

You may also be interested in

ELISA
Product image
Mouse Interferon gamma ELISA Kit (IFNG) (ab100690)
Primary
Product image
Anti-ketohexokinase antibody [EPR15847] (ab197593)
Assay
Product image
D-Lactate Assay Kit (Colorimetric) (ab83429)

View more associated products

Overview

  • Product name

    Ammonia Assay Kit
    See all Ammonia kits
  • Detection method

    Colorimetric
  • Sample type

    Urine, Serum, Plasma, Other biological fluids, Tissue Extracts, Cell Lysate, Cell culture media
  • Assay type

    Quantitative
  • Sensitivity

    20 µM
  • Assay time

    1h 00m
  • Product overview

    Ammonia Assay Kit (ab83360) provides a rapid, simple, sensitive, and reliable assay for ammonia and ammonium.


    In the ammonia assay protocol, ammonia and ammonium are converted to a product that reacts with a probe to generate color (λmax = 570 nm) which can be easily quantified by plate reader. The kit can detect 1 nmol (~20 µM) of total ammonia and ammonium, which is much more sensitive than measuring ammonia with a NADPH based assay.


    Ammonia assay protocol summary:
    - add samples and standards to wells
    - add reaction mix and incubate for 60 min at 37ºC
    - analyze with microplate reader

  • Notes

    This product is manufactured by BioVision, an Abcam company and was previously called K370 Ammonia Colorimetric Assay Kit. K370-100 is the same size as the 100 test size of ab83360.

    Ammonia assays measure the total level of the ammonium ion and of ammonia in a sample.

    At a physiological pH, nearly all ammonia exists as ammonium in solution.

    The chemical equation that drives the relationship between ammonia and ammonium is: NH3 + H2O ↔ NH4+ + OH-

    When the pH is low, the reaction is driven to the right, and when the pH is high, the reaction is driven to the left. In general, at around room temperature, at a pH less than 6.0, the proportion of ammonium-N plus ammonia-N as NH3 is very low and as NH4+ is very high. At a pH around 8.0 (the ammonia assay buffer pH), the proportion as NH3 is 10 percent or less.

    This is our most popular ammonia assay kit; ammonia assay kit ab102509 uses an alternative non-enzymatic method.

    How other researchers have used Ammonia Assay Kit ab83360

    The ammonia assay kit has been used in publications in a variety of sample types, including:
    - Human: A549, 293T and U2OS cell culture lysates1; A549 cell culture medium2
    - Mouse: brain, liver tissue and serum3; plasma4; pancreas, kidney, liver, brain, and muscle tissue5; faeces6
    - Bacteria: B. pertussis cultures7
    - Cell culture medium8 

    References: 1 - Xu S et al 2019, Spinelli JB et al 2017, Trempolec N et al 2017; 2 - Jin L et al 2018; 3 - Wilson et al 2018; 4 - Khoja S et al 2018, Cantero et al 2016; 5 - Gutierrez-de-Jua V et al 2017; 6 - Shen et al 2016; 7 - Fyson et al 2017; 8 - Li et al 2016

  • Platform

    Microplate reader

Properties

  • Storage instructions

    Store at -20°C. Please refer to protocols.
  • Components Identifier 100 tests
    Ammonia Assay Buffer WM 1 x 25ml
    Converting Enzyme (Lyophilized) Blue 1 vial
    Developer Orange 1 vial
    Enzyme Mix (Lyophilized) Green 1 vial
    NH4Cl Standard Yellow 1 x 100µl
    OxiRed Probe in DMSO Red 1 x 200µl
  • Research areas

    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Amino Acid Assays
    • Kits/ Lysates/ Other
    • Kits
    • Cell Signaling Kits
    • Ions and Metal Assay Kits
  • Relevance

    Ammonia is an important source of nitrogen for living systems. Nitrogen is required for the synthesis of amino acids, which are the building blocks of protein. Ammonia is a metabolic product which is created through amino acid deamination. It plays an important role in both normal and abnormal animal physiology like normal animal acid/base balance.

Images

  • Ammonia Assay Kit ab83360 used with cell culture media
    Ammonia Assay Kit ab83360 used with cell culture mediaLi, Zhiyuan et al., PloS one vol. 11,4 e0153526., Fig 1

    Zhiyuan Li et al. used ammonia assay kit ab83360 to examine the build-up of ammonia in old cell culture medium containing glutamine and how this might induce autophagy in cultured cells. 

    The ammonia assay was used to measure the ammonia concentration in cell culture medium containing Glutamine (medium alone, without cells) which was stored at 4°C or at 37°C for between 1-7 days. They found that ammonia levels increased significantly in the medium stored at 37°C.

  • Ammonia Assay Kit ab83360 used with liver tissue
    Ammonia Assay Kit ab83360 used with liver tissueWilson, Kyle D et al., Journal of neuroinflammation vol. 15,1 173., Additional file 2

    Kyle Wilson et al. used ammonia assay kit ab83360 to examine ammonia levels in liver tissue in response to P. chabaudi infection. They found that in IL-10 KO mice, ammonia levels were not elevated above WT during P. chabaudi infection.

    WT and IL-10 KO mice were infected with P. chabaudi and monitored during the peak of infection. WT mice were sacrificed at the peak of infection (day 10 p.i.) and IL-10 KO mice upon severe morbidity as determined via SHIRPA score.

  • Ammonia Assay Kit ab83360 used with cell culture media
    Ammonia Assay Kit ab83360 used with cell culture media

    Ammonia assay performed with cell culture medium (range of dilution 1:10-1:200) and control medium (range of dilution 1:1-1:20), background signal subtracted (duplicates +/- SD).

  • Ammonia Assay Kit ab83360 used with tissue lysates
    Ammonia Assay Kit ab83360 used with tissue lysates

    Ammonia assay performed with mouse tissue lysates (mg of extracted protein), background signal subtracted (duplicates +/- SD).

  • Ammonia Assay Kit ab83360 used with lysates of cultured cells
    Ammonia Assay Kit ab83360 used with lysates of cultured cells

    Ammonia assay performed in cell lysates, background signal subtracted (duplicates +/- SD).

  • Ammonia Assay Kit ab83360 used with biofluid samples
    Ammonia Assay Kit ab83360 used with biofluid samples

    Ammonia assay performed in biological fluids (range of dilution 1:1-1:100), background signal subtracted (duplicates +/- SD).

  • Ammonia assay standard curve
    Ammonia assay standard curve

    Example of ammonia assay standard curve using ab83360

Protocols

  • Protocol Booklet

Click here to view the general protocols

Datasheets and documents

  • SDS download

  • Datasheet download

    Download

References (38)

Publishing research using ab83360? Please let us know so that we can cite the reference in this datasheet.

ab83360 has been referenced in 38 publications.

  • Allen SL  et al. The Effect of Ex Vivo Human Serum from Liver Disease Patients on Cellular Protein Synthesis and Growth. Cells 11:N/A (2022). PubMed: 35406665
  • Murata K  et al. Rifaximin enhances the L-carnitine-mediated preventive effects on skeletal muscle atrophy in cirrhotic rats by modulating the gut-liver-muscle axis. Int J Mol Med 50:N/A (2022). PubMed: 35686541
  • Khoja S  et al. Intermittent lipid nanoparticle mRNA administration prevents cortical dysmyelination associated with arginase deficiency. Mol Ther Nucleic Acids 28:859-874 (2022). PubMed: 35694211
  • Soria LR  et al. O-GlcNAcylation enhances CPS1 catalytic efficiency for ammonia and promotes ureagenesis. Nat Commun 13:5212 (2022). PubMed: 36064721
  • Wu B  et al. ADSCs-derived exosomes ameliorate hepatic fibrosis by suppressing stellate cell activation and remodeling hepatocellular glutamine synthetase-mediated glutamine and ammonia homeostasis. Stem Cell Res Ther 13:494 (2022). PubMed: 36195966
View all Publications for this product

Customer reviews and Q&As

Show All Reviews Q&A
Submit a review Submit a question

1-10 of 12 Abreviews or Q&A

COMPATIBILITY OF THE KIT WITH ORGANIC SOLVENTS

Excellent Good 4/5 (Ease of Use)
Abreviews
Abreviews
abreview image
The ammonia determination is accurate for samples of tissue extracted in methanol:acetonitrile:water (5:3:2) solution, provided that the samples are diluted 1:5 in assay buffer. The reaction efficiency decreases when the ratio between organic solvents and assay buffer increases. The reaction does not occur if the samples in organic solvents are not further diluted in assay buffer.
Figure Legend. The standard curve has been generated by mixing in each well 10 microliters of methanol, acetonitrile, water, solution containing known amounts of ammonia, to 40 microliters of assay buffer. The reaction started with the addition of 50microliters/well of reaction mix. Samples were incubated at 37 degrees for 1 hour.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

Submitted Jul 27 2016

The ABCAM ammonia kit can be used for the in situ detection of ammonia

Good Good 4/5 (Ease of Use)
Abreviews
Abreviews
We had good results using the ABCAM ammonia kit for the detection of NH3 in our cell lysates. However, we wanted to see the distribution of NH3 in the intact cells to determine the intercellular variation. We were able to adapt the kit to allow for the in situ detection of ammonia. We chose two cell lines one strongly + for NH3 and one -. The key was to use formalin fixed cells AND to digest in protease prior to use. Under these conditions, we got an excellent signal in the + cells and no signal in the - cells.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

Submitted Dec 27 2013

Question

In the literature attached with the product, it talks about ‘ammonia’, yet the data analysis section gives reference to ‘ammonium’ – the form of ammonia we are interested in. So is this kit giving us a concentration of NH4+ ammonium or NH3 ammonia?

Read More

Abcam community

Verified customer

Asked on Oct 23 2013

Answer

The kit detects Ammonia which would exist as ammonium ion in solution. The detection principle is based on reaction with ammonium ion in solution. This ammonium ion population includes free pre-existing cellular ammonium and the ionized form of ammonia. To subtract background from pre-existing ammonium, run a parallel reaction excluding the converting enzyme. This would also allow subtraction of any interference from endogenous Pyruvate.

This kit therefore measures total ammonium in solution. At physiological pH, nearly all ammonia will exist as ammonium in solution.

The chemical equation that drives the relationship between ammonia and ammonium is:

NH3 + H2O ↔ NH4+ + OH-

When the pH is low, the reaction is driven to the right, and when the pH is high, the reaction is driven to the left. In general, at around room temperature, at a pH less than 6.0, the proportion of ammonium-N plus ammonia-N as NH3 is very-very low and as NH4+ is very-very high. At a pH around 8.0 (the assay buffer pH), the proportion as NH3 is 10 percent or less. Laboratory methods measure ammonium-N plus ammonia-N. It is very difficult to directly determine the activity of aqueous ammonia, so instead the surrogate of ammonium-N plus ammonia-N is used.

Controls:

1. If any buffer used in the experiment has ammonium salt (e.g. NH4Cl), the buffer must be used to assay how much ammonium is in it. This number can be subtracted from the cells + buffer number to know how much ammonium is in the cells.

2. Also, the zero standard gives the background reading for contamination from ammonia in air.

3. Omitting the converting enzyme gives background from pyruvate which is an intermediate in the colour development reaction.

Read More

Elisa Thomas

Abcam Scientific Support

Answered on Oct 23 2013

Question

1. Is pH of the sample an important consideration when using this kit?
2. Can you recommend a protocol for preparing mouse stool samples for use with this kit?

Read More

Abcam community

Verified customer

Asked on Apr 15 2013

Answer

Thank you for contacting us.
In response to your questions on this kit, the pH of the sample should be ˜7-8. To use mouse stool sample, add assay buffer to sample. Mix it completely either by pipetting up & down, sonicating or vortexing. Centrifuge to remove insoluble material & use the supernatant to do the assay according to the protocol mentioned in the datasheet.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

Answered on Apr 15 2013

Question

Does your ammonia assay also detect ammonium?

Read More

Abcam community

Verified customer

Asked on Jun 12 2012

Answer

This kit measures the total ammonia + ammonium concentration in your samples. Ammonium does not interfere with this assay.

The actual method and way the kit does this is proprietary information and so I am unable to provide more information.

Please let me know if there is anything else I can help you with.

Read More

Abcam Scientific Support

Answered on Jun 12 2012

Question

Can this kit be used with phenol red-containing medium?

Read More

Abcam community

Verified customer

Asked on Dec 22 2011

Answer

Phenol red containing media can interfere with the results of this assay. Diluting the media samples with assay buffer may help reduce the concentration of the phenol red thus minimizing the background.

My advice is to switch to medium that is phenol red-free. I think you mentioned that you were using RPMI, which is available in that formulation.

Read More

Abcam Scientific Support

Answered on Dec 22 2011

Question

We`re planning to buy Ammonia Assay Kit for measure the ammonia content in batch culture samples.

Is this kit appropriate for this sample type? Do I need centrifuge the sample before freezing, because I would like to do the measurment later.

Read More

Abcam community

Verified customer

Asked on Mar 26 2015

Answer

For this kit, we prefer measuring from fresh samples for best results but cell culture media can be centrifuged to remove any debris and then stored at -80C for future assay.

Read More

Sam Washer

Abcam Scientific Support

Answered on Mar 26 2015

Question

I plan to detect Ammonia in mouse serum sample. Do you have any special suggestions on how to prepare blood sample?

Read More

Abcam community

Verified customer

Asked on May 02 2013

Answer

For serum or plasma samples, there are no special requirements for preparation of serum or plasma samples for the ammonia assay.

Read More

Abcam Scientific Support

Answered on May 02 2013

Question

what tissue was the kit tested on?

Read More

Abcam community

Verified customer

Asked on Sep 11 2012

Answer

Thank you for contacting us.

This kit has been tested on mouse brain, heart, liver kidney and muscle tissues. Please see figure 3 in the protocol booklet for more information.
Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

Answered on Sep 11 2012

Question

My samples will be collected in twos and threes. It would be inefficient to use the kit until I have enough samples for a whole plate. Can I aliquot and store my serum samples at -80 C until then?

Read More

Abcam community

Verified customer

Asked on Aug 20 2012

Answer

Thank you for contacting us.

Yes, storage at -80 C until you are ready to perform the assay will be fine.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

Answered on Aug 20 2012

1-10 of 12 Abreviews or Q&A

  •  Previous
  • 1
  • 2
  • Next 

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Get resources and offers direct to your inbox Sign up
A-Z by research area
  • Cancer
  • Cardiovascular
  • Cell biology
  • Developmental biology
  • Epigenetics & Nuclear signaling
  • Immunology
  • Metabolism
  • Microbiology
  • Neuroscience
  • Signal transduction
  • Stem cells
A-Z by product type
  • Primary antibodies
  • Secondary antibodies
  • Biochemicals
  • Isotype controls
  • Flow cytometry multi-color selector
  • Kits
  • Loading controls
  • Lysates
  • Peptides
  • Proteins
  • Slides
  • Tags and cell markers
  • Tools & Reagents
Help & support
  • Support
  • Make an Inquiry
  • Protocols & troubleshooting
  • Placing an order
  • RabMAb products
  • Biochemical product FAQs
  • Training
  • Browse by Target
Company
  • Corporate site
  • Investor relations
  • Company news
  • Careers
  • About us
  • Blog
Events
  • Tradeshows
  • Conferences
International websites
  • abcam.cn
  • abcam.co.jp

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
  • Modern slavery statement
© 1998-2023 Abcam plc. All rights reserved.