For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Customized Products & Partnerships
    Customized Products & Partnerships

    Customized products and commercial partnerships to accelerate your diagnostic and therapeutic programs.

    Customized products

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

  1. Link

    products/assay-kits/complex-iv-rodent-immunocapture-kit-ab109860.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Signal Transduction Metabolism Mitochondrial
Share by email

Complex IV Rodent Immunocapture Kit (ab109860)

  • Datasheet
  • SDS
  • Protocol Booklet
Submit a review Q&A (4)References (1)

Product price, shipping and contact information

Currently unavailable

Sorry, we can't display this right now.

Please contact us to place your order, or try again later.

 

Loading size & price…

 

Shipping and order information

Shipping info

Promotion Information

Abpromise

Guaranteed product quality, expert customer support.

Find out more.

You may also be interested in

Assay
Product image
Complex IV Human Enzyme Activity Dipstick Assay Kit (ab109876)
Assay
Product image
Complex II Enzyme Activity Microplate Assay Kit (ab109908)
Cocktail
Product image
Total OXPHOS Rodent WB Antibody Cocktail (ab110413)

View more associated products

Overview

  • Product name

    Complex IV Rodent Immunocapture Kit
    See all Complex IV kits
  • Species reactivity

    Reacts with: Mouse, Rat
  • Product overview

    Complex IV Rodent Immunocapture Kit ab109860 allows for isolation of the cytochrome c oxidase complex from small amounts of tissue. 


    250 µg, 500 µg or 750 µg monoclonal antibodies irreversibly crosslinked to protein G-agarose beads which can immunocapture ~25 µg, ~50 µg or ~75 µg respectively of Complex IV from heart mitochondria.


     This kit facilitates the analysis of both assembly state and accrued post-translational modifications of all 13 subunits of the cytochrome c oxidase complex. The immunoprecipitated Complex IV shows cytochrome c oxidase activity while bound to the beads and this activity is fully sensitive to cyanide. Uses for ab109860 include but are not limited to examining alterations of Complex IV subunits in inherited mitochondrial diseases, Alzheimer's disease, schizophrenia and cancer.


     


    Note: The immunocapture protocol for this kit requires Abcam detergent lauryl maltoside (ab109857/MS910).


     

  • Notes

    Related products

    Review the mitochondrial assay guide, or the full metabolism assay guide to learn about more assays for metabolites, metabolic enzymes, mitochondrial function, and oxidative stress, and also how to assay metabolic function in live cells using your plate reader.

Properties

  • Storage instructions

    Store at +4°C. Please refer to protocols.
  • Components 250 µg
    monoclonal antibody irreversibly crosslinked to protein G-agarose beads 1 x 250µg
  • Research areas

    • Signal Transduction
    • Metabolism
    • Mitochondrial
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Other Metabolism Assay
    • Metabolism
    • Pathways and Processes
    • Mitochondrial Metabolism
    • Mitochondrial markers
    • Metabolism
    • Pathways and Processes
    • Mitochondrial Metabolism
    • Cytochromes
    • Kits/ Lysates/ Other
    • Kits
    • Immunocapture
    • OXPHOS
  • Alternative names

    • cco
    • COX
    • Cytochrome c oxidase
    • Cytochrome oxidase

Associated products

  • Related Products

    • 10% Lauryl Maltoside Solution (ab109857)

Protocols

  • Protocol Booklet

Click here to view the general protocols

Datasheets and documents

  • SDS download

  • Datasheet download

    Download

References (1)

Publishing research using ab109860? Please let us know so that we can cite the reference in this datasheet.

ab109860 has been referenced in 1 publication.

  • Strub GM  et al. Sphingosine-1-phosphate produced by sphingosine kinase 2 in mitochondria interacts with prohibitin 2 to regulate complex IV assembly and respiration. FASEB J 25:600-12 (2011). PubMed: 20959514

Customer reviews and Q&As

Show All Reviews Q&A
Submit a review Submit a question

1-4 of 4 Abreviews or Q&A

Question

Hello.
I have purchased the product: Complex IV Rodent Immunocapture Kit. After several experiemnts with their
respective controls we have conclude that is not working. May be during the delivery proccess the Kit
have been spoiled or damaged as Complex I Immunocapture Kit (also purchase to Mitoscience) works nicely.
Please, consider to send us other kit.

Read More

Abcam community

Verified customer

Asked on Jan 17 2012

Answer

I am very sorry but, based on the lot number you provided, it appears you receivedthe IP reagent for ab109801, which only works with HUMAN and COW samples. Youunfortunately did not receive the IP reagent forab109860, a complex IV immunocapture kit suitable for RODENT SAMPLES.

Of course I will be happy to send youfree replacement kitforuse with your rodent samples,ab109860. If you could, please provide thepurchase order number or Abcam order reference number associated with the purchase of this kit so I can process the replacement.

Thanks for your patience with our troubelshooting process and again I am very sorry for this mistake. We will get you the newkit as soon as possible.

Read More

Abcam Scientific Support

Answered on Jan 17 2012

Question

Hello. I have purchased the product: Complex IV Rodent Immunocapture Kit. After several experiemnts with their respective controls we have conclude that is not working. May be during the delivery proccess the Kit have been spoiled or damaged as Complex I Immunocapture Kit (also purchase to Mitoscience) works nicely. Please, consider to send us other kit.

Read More

Abcam community

Verified customer

Asked on Jan 13 2012

Answer

I am very sorry to hear there is a problem here. If you could, a few additional details would be helpful to help us determine what the problems may be: 1. Canyou addmolecular weight markers and show the full gel so we can see the top of the blot. 2.What is the lot number of this kit (so we can check the QC data)? 3. Some protocol details, including: a. How sample was prepped? b. Is input the sample before extraction or post extraction? c. How were the beads eluted? Thanks very much for the additional information!

Read More

Abcam Scientific Support

Answered on Jan 13 2012

Question

Hello. I attach a file from IP experiments. You`ll see how while using Complex I Immunocapture kit i succeed in Immunocapturing CI (WB against NDUFA9) but i also Immunocapture complex IV, (WB against COX4), but with Complex IV Immunocapture ki,t i Immunocapture nothing. I have used the right detergent and concentrations. I can not explain that result but thinking something is wrong with the kit.

Read More

Abcam community

Verified customer

Asked on Dec 01 2011

Answer

Thank you for sending along your IP/western blot data. It does appear the IP of  complex IV is not working. If you have purchased this kit within the last 6 months or so I would be happy to send you a new kit. So I can process your request, please include the PO number or Abcam order reference number associated with this order.  

Read More

Abcam Scientific Support

Answered on Dec 01 2011

Question

Hello. I have purchased the product: Complex IV Rodent Immunocapture Kit. After several experiemnts with their respective controls we have conclude that is not working. May be during the delivery proccess the Kit have been spoiled or damaged as Complex I Immunocapture Kit (also purchase to Mitoscience) works nicely. Please, consider to send us other kit.

Read More

Abcam community

Verified customer

Asked on Nov 30 2011

Answer

Thank you for your enquiry. I'm sorry to hear the Complex IV Immunocapture kit is giving you trouble. I think it would be helpful if you could give a few more details describing how the kit is not working. Including an attached figure would be quite useful as well. Thanks in advance for the additional information.

Read More

Abcam Scientific Support

Answered on Nov 30 2011

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Get resources and offers direct to your inbox Sign up
A-Z by research area
  • Cancer
  • Cardiovascular
  • Cell biology
  • Developmental biology
  • Epigenetics & Nuclear signaling
  • Immunology
  • Metabolism
  • Microbiology
  • Neuroscience
  • Signal transduction
  • Stem cells
A-Z by product type
  • Primary antibodies
  • Secondary antibodies
  • Biochemicals
  • Isotype controls
  • Flow cytometry multi-color selector
  • Kits
  • Loading controls
  • Lysates
  • Peptides
  • Proteins
  • Slides
  • Tags and cell markers
  • Tools & Reagents
Help & support
  • Support
  • Make an Inquiry
  • Protocols & troubleshooting
  • Placing an order
  • RabMAb products
  • Biochemical product FAQs
  • Training
  • Browse by Target
Company
  • Corporate site
  • Investor relations
  • Company news
  • Careers
  • About us
  • Blog
Events
  • Tradeshows
  • Conferences
International websites
  • abcam.cn
  • abcam.co.jp

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
  • Modern slavery statement
© 1998-2023 Abcam plc. All rights reserved.