For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Customized Products & Partnerships
    Customized Products & Partnerships

    Customized products and commercial partnerships to accelerate your diagnostic and therapeutic programs.

    Customized products

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

  1. Link

    products/primary-antibodies/fitc-mouse-igg1-b116-isotype-control-ab91356.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Isotype/Loading Controls Isotype Controls Mouse
Share by email

FITC Mouse IgG1 [B11/6] - Isotype Control (ab91356)

  • Datasheet
  • SDS
Q&A (3)References (9)

Product price, shipping and contact information

Currently unavailable

Sorry, we can't display this right now.

Please contact us to place your order, or try again later.

 

Loading size & price…

 

Shipping and order information

Shipping info

Promotion Information

Abpromise

Guaranteed product quality, expert customer support.

Find out more.

Conjugates logo Related conjugates and formulations

CF405M PE PerCP Unconjugated

You may also be interested in

Conjugation
Product image
FITC Conjugation Kit - Lightning-Link® (ab102884)
Isotype
Product image
PE Rabbit IgG, monoclonal [EPR25A] - Isotype Control (ab209478)
Primary
Product image
FITC Anti-CD34 antibody [QBEND/10] (ab78165)

View more associated products

Overview

  • Product name

    FITC Mouse IgG1 [B11/6] - Isotype Control
    See all Mouse isotype controls
  • Conjugation

    FITC. Ex: 493nm, Em: 528nm
  • Specificity

    ab91356 was produced against a synthetic hapten, which is normally not present in Humans or animals. Therefore, this mouse IgG1 does not react with any antigen of Human or animal cells.
  • Tested applications

    Suitable for: Flow Cytmore details
  • Immunogen

    Vegetal protein

  • General notes

    The Life Science industry has been in the grips of a reproducibility crisis for a number of years. Abcam is leading the way in addressing this with our range of recombinant monoclonal antibodies and knockout edited cell lines for gold-standard validation. Please check that this product meets your needs before purchasing.

    If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, along with publications, customer reviews and Q&As

Properties

  • Form

    Liquid
  • Storage instructions

    Shipped at 4°C. Store at +4°C. Store In the Dark.
  • Storage buffer

    pH: 7.20
    Preservative: 0.1% Sodium azide
    Constituents: PBS, 1% BSA
  • Concentration information loading...
  • Purity

    Protein G purified
  • Clonality

    Monoclonal
  • Clone number

    B11/6
  • Isotype

    IgG1
  • Research areas

    • Isotype/Loading Controls
    • Isotype Controls
    • Mouse
  • Alternative names

    • Mouse Isotype Control

Associated products

  • Alternative Versions

    • PerCP Mouse IgG1, Kappa Monoclonal [B11/6] - Isotype Control (ab118658)
    • CF405M Mouse IgG1, Kappa Monoclonal [B11/6] - Isotype Control (ab126026)
    • Mouse IgG1, Kappa Monoclonal [B11/6] - Isotype Control (ab91353)
    • PE Mouse IgG1 [B11/6] - Isotype Control (ab91357)
  • Compatible Secondaries

    • Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) (ab150113)
    • Goat Anti-Mouse IgG H&L (HRP) (ab205719)

Applications

The Abpromise guarantee

Our Abpromise guarantee covers the use of ab91356 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
Flow Cyt
Use at an assay dependent concentration.

ab91356 is a negative isotype control.

Notes
Flow Cyt
Use at an assay dependent concentration.

ab91356 is a negative isotype control.

Protocols

  • Flow cytometry protocols

Click here to view the general protocols

Datasheets and documents

  • SDS download

  • Datasheet download

    Download

References (9)

Publishing research using ab91356? Please let us know so that we can cite the reference in this datasheet.

ab91356 has been referenced in 9 publications.

  • Santoro F  et al. Isolation of human ESC-derived cardiac derivatives and embryonic heart cells for population and single-cell RNA-seq analysis. STAR Protoc 2:100339 (2021). PubMed: 33644774
  • Chamberlain N  et al. Lung epithelial protein disulfide isomerase A3 (PDIA3) plays an important role in influenza infection, inflammation, and airway mechanics. Redox Biol 22:101129 (2019). PubMed: 30735910
  • Ode Y  et al. Cold-inducible RNA-binding Protein Induces Neutrophil Extracellular Traps in the Lungs during Sepsis. Sci Rep 9:6252 (2019). PubMed: 31000768
  • Zhang L  et al. Hypoxia preconditioned renal tubular epithelial cell-derived extracellular vesicles alleviate renal ischaemia-reperfusion injury mediated by the HIF-1a/Rab22 pathway and potentially affected by microRNAs. Int J Biol Sci 15:1161-1176 (2019). PubMed: 31223277
  • Khan MA  et al. C5a Blockade Increases Regulatory T Cell Numbers and Protects Against Microvascular Loss and Epithelial Damage in Mouse Airway Allografts. Front Immunol 9:1010 (2018). PubMed: 29881374
  • Tomlinson JE  et al. Multispectral fluorescence-activated cell sorting of B and T cell subpopulations from equine peripheral blood. Vet Immunol Immunopathol 199:22-31 (2018). PubMed: 29678226
  • Liu H  et al. Human umbilical vein endothelial cell vaccine suppresses the angiogenesis of esophageal squamous cell carcinoma in a humanized mouse model. Oncol Rep 40:3006-3014 (2018). PubMed: 30132560
  • Sun W  et al. Proanthocyanidins Attenuation of H2O2-Induced Oxidative Damage in Tendon-Derived Stem Cells via Upregulating Nrf-2 Signaling Pathway. Biomed Res Int 2017:7529104 (2017). PubMed: 29201913
  • Lau WH  et al. Combinatorial treatment with polyI:C and anti-IL6 enhances apoptosis and suppresses metastasis of lung cancer cells. Oncotarget 8:32884-32904 (2017). PubMed: 28427199

Customer reviews and Q&As

Q&A
Submit a question

1-3 of 3 Q&A

Question

Could you tell me the volume per vial of the isotype control ab91356? On your website it is only stated “50 tests”. Could you confirm the antibody concentration of 0.05 mg/ml as well?

Read More

Abcam community

Verified customer

Asked on Jan 30 2018

Answer

The volume per vial of ab91356 is 1 ml. It is possible to perform 50 tests, as 20 µl is required per test.
I also confirm the concentration of our current vials in stock are at 0.05 mg/ml.

Read More

Abcam Scientific Support

Answered on Jan 30 2018

Question

What is the concentration of lot GR65536?

Read More

Abcam community

Verified customer

Asked on Jul 24 2012

Answer

Thank youvery much for your call yesterday and for your patience while I have looked into your enquiry.



I've heard back from the lab, and the concentration of this product is 0.025 mg/ml.



I hope this information will be useful, but if you have further questions or if there is anything else that we can do for you, please let me know and I'll be happy to help.

Read More

Abcam Scientific Support

Answered on Jul 24 2012

Question

Dear Sir/ Madam
Please check the below quiry and help us.
"I am planning to use Anti - CD18 antibody [CLB-LFA-1/1,54] (FITC) (ab51573) antibody for my work, if i have to use a negative control, will this isotype control - Mouse IgG1 [ICIG1] – Isotype Control (ab91356) work well with it? is it compatible as reference for Anti - CD18 antibody [CLB-LFA-1/1,54] (FITC) (ab51573). If not what alternative isotype control should i go for.?"
Regards

Read More

Abcam community

Verified customer

Asked on Feb 19 2013

Answer

Thank you for contacting us.

I can confirm that ab91356 (Mouse IgG1 [ICIG1] (FITC) – Isotype Control) can be used as a negative isotype control for ab51573 (Anti-CD18 antibody [CLB-LFA-1/1, 54] (FITC)) with Flow Cytometry.

I hope this helps. Please let us know if you know further assistance.

Read More

Abcam Scientific Support

Answered on Feb 19 2013

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Get resources and offers direct to your inbox Sign up
A-Z by research area
  • Cancer
  • Cardiovascular
  • Cell biology
  • Developmental biology
  • Epigenetics & Nuclear signaling
  • Immunology
  • Metabolism
  • Microbiology
  • Neuroscience
  • Signal transduction
  • Stem cells
A-Z by product type
  • Primary antibodies
  • Secondary antibodies
  • Biochemicals
  • Isotype controls
  • Flow cytometry multi-color selector
  • Kits
  • Loading controls
  • Lysates
  • Peptides
  • Proteins
  • Slides
  • Tags and cell markers
  • Tools & Reagents
Help & support
  • Support
  • Make an Inquiry
  • Protocols & troubleshooting
  • Placing an order
  • RabMAb products
  • Biochemical product FAQs
  • Training
  • Browse by Target
Company
  • Corporate site
  • Investor relations
  • Company news
  • Careers
  • About us
  • Blog
Events
  • Tradeshows
  • Conferences
International websites
  • abcam.cn
  • abcam.co.jp

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
  • Modern slavery statement
© 1998-2023 Abcam plc. All rights reserved.