For the best experience on the Abcam website please upgrade to a modern browser such as Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
United States
Your country/region is currently set to:

If incorrect, please enter your country/region into the box below, to view site information related to your country/region.

Call (888) 77-ABCAM (22226) or contact us
Need help? Contact us

  • My account
  • Sign out
Sign in or Register with us

Welcome

Sign in or

Don't have an account?

Register with us
My basket
Quick order
Abcam homepage

  • Research Products
    By product type
    Primary antibodies
    Secondary antibodies
    ELISA and Matched Antibody Pair Kits
    Cell and tissue imaging tools
    Cellular and biochemical assays
    Proteins and Peptides
    By product type
    Proteomics tools
    Agonists, activators, antagonists and inhibitors
    Cell lines and Lysates
    Multiplex miRNA assays
    Multiplex Assays
    By research area
    Cancer
    Cardiovascular
    Cell Biology
    Epigenetics
    Metabolism
    Developmental Biology
    By research area
    Immunology
    Microbiology
    Neuroscience
    Signal Transduction
    Stem Cells
  • Customized Products & Partnerships
    Customized Products & Partnerships

    Customized products and commercial partnerships to accelerate your diagnostic and therapeutic programs.

    Customized products

    Partner with us

  • Support
    Support hub

    Access advice and support for any research roadblock

    View support hub

    Protocols

    Your experiments laid out step by step

    View protocols

  • Events
    • Conference calendar
    • Cancer
    • Cardiovascular
    • Epigenetics & Nuclear signaling
    • Immunology
    • Neuroscience
    • Stem cells
    • Tradeshows
    • Scientific webinars
    Keep up to date with the latest events

    Full event breakdown with abstracts, speakers, registration and more

    View global event calendar

  • Pathways
    Cell signalling pathways

    View all pathways

    View all interactive pathways

Flow cytometry troubleshooting tips

Related

  • Flow cytometry resources
    • Introduction to flow cytometry
      • Flow cytometry training
        • Indirect flow cytometry protocol
          • Direct flow cytometry protocol
            • Multicolor flow cytometry guide
                • Products for your research
                  • Conjugated antibodies for flow cytometry
                      • Support
                        • How do I analyze my flow cytometry data?
                            • Register for updates

                              Detailed troubleshooting techniques to help you resolve flow cytometry issues.

                              View a PDF version of this page

                              Contents:

                              1. No signal/weak fluorescence intensity
                              2. High fluorescence intensity
                              3. High background/high percentage of positive cells
                              4. Two or more cell populations observed when there should be one
                              5. High side scatter background (from small particles)
                              6. Low event rate
                              7. High event rate


                              1. No signal/weak fluorescence intensity

                              Signal not correctly compensated
                              Check positive single color control is set up correctly on flow cytometer, gated and compensated correctly to capture all the events.

                              Insufficient antibody present for detection
                              Increase amount/concentration of antibody.

                              Intracellular target not accessible
                              Check if target protein is intracellular. For internal staining, ensure adequate permeabilization (we recommend our Fix and Perm Cell Fixation and Permeabilization Kit ab185917). To prevent internalisation of cell surface proteins, everything must be done on ice or at 4°C, with ice cold reagents, to stop all reactions.

                              Adding sodium azide will prevent the modulation and internalization of surface antigens which can produce a loss of fluorescence intensity. For staining of cell lines, trypsin can often induce internalisation of cell surface proteins, particularly cell surface molecules, and more gentle detachment methods may be required.

                              Intracellular staining – fluorochrome conjugate too large
                              Fluorochromes for intracellular staining experiments should have low molecular weight. Large molecular weight flourochromes can reduce antibody motility and possibly its entry into the cell.

                              Lasers not aligned
                              Ensure lasers on flow cytometer are aligned correctly by running flow check beads and adjusting alignment if necessary. If the lasers do not align correctly or if drift occurs, you may need to consider having the machine serviced.

                              Target protein not present/expressed at low level
                              Ensure tissue/cell type expresses target protein and that it is present in a high enough amount to detect.

                              Soluble/secreted target protein
                              Is the target protein soluble and secreted from the cell? It needs to be membrane bound or cytoplasmic to be detected easily by flow cytometry. A golgi-block step, such as with Brefeldin A, may improve the signal achieved for intracellular staining.

                              Offset too high/gain too low
                              Use the positive control to set up the flow cytometer correctly again, using the offset to ensure the fluorescent signal from cells is not being cut off, and increase the gain to increase the signal (within reason – care should be taken).

                              Fluorochrome fluorescence has faded
                              Antibody may have been kept for too long or left out in the light. Fresh antibody will be required.

                              The primary antibody and the secondary antibody are not compatible
                              Use secondary antibody that was raised against the species in which the primary was raised (e.g primary is raised in rabbit, use anti-rabbit secondary).

                              2. High fluorescence intensity

                              Antibody concentration too high
                              This will give high, non-specific binding or very high intensity of fluorescence. Reduce the amount of antibody added to each sample.

                              Excess antibody trapped
                              This can be a particular problem in intracellular staining where large fluorochrome molecules on the antibody can be trapped. Ensure adequate washing steps and include tween or triton in wash buffers.

                              Inadequate blocking
                              Add 1% to 3% blocking agent with antibody as well as a blocking step.

                              3. High background/high percentage of positive cells

                              Gain set too high/offset too low
                              Use the positive control to set up the flow cytometer correctly again, using the offset to reduce background from small particles and reduce the gain to decrease the signal.

                              Excess antibody
                              Decrease the antibody concentration. Detergent can also be added to the wash buffers to ensure any excess antibody is washed away.

                              4. Two or more cell populations observed when there should be just one

                              More than one cell population present expressing target protein
                              Check expected expression levels from the cell types contained in the sample and ensure adequate cell separation if necessary.

                              Cell doublets present
                              Doublets of cells will show as a second cell population at approximately twice the fluorescence intensity on the plot. Mix cells gently before staining and again before running on the cytometer using a pipette. Cells can also be sieved or filtered to remove clumps (30 μl Nylon Mesh).

                              5. High side scatter background (from small particles)

                              Cells lysed
                              Ensure cells in the sample have not lysed and broken up. Samples should be fresh and prepared correctly. Do not centrifuge cells at a high rotor speed or vortex too violently.

                              Bacterial contamination
                              Ensure sample is not contaminated. Bacteria will auto fluoresce at low level. This will also give a high event rate.

                              6. Low event rate

                              Low number of cells/ml
                              Run 1x106 cells/ml. Ensure cells are mixed well (but gently).

                              Cells clumped, blocking tubing
                              Ensure a homologous single cell suspension by pipetting gently several times before staining. Ensure you mix again before running. In extreme cases, cells can be sieved or filtered to remove clumps (30 μl Nylon Mesh).

                              7. High event rate

                              High number of cells
                              Dilute to between 1x105 and 1x106 cells/ml.


                              Get resources and offers direct to your inbox Sign up
                              A-Z by research area
                              • Cancer
                              • Cardiovascular
                              • Cell biology
                              • Developmental biology
                              • Epigenetics & Nuclear signaling
                              • Immunology
                              • Metabolism
                              • Microbiology
                              • Neuroscience
                              • Signal transduction
                              • Stem cells
                              A-Z by product type
                              • Primary antibodies
                              • Secondary antibodies
                              • Biochemicals
                              • Isotype controls
                              • Flow cytometry multi-color selector
                              • Kits
                              • Loading controls
                              • Lysates
                              • Peptides
                              • Proteins
                              • Slides
                              • Tags and cell markers
                              • Tools & Reagents
                              Help & support
                              • Support
                              • Make an Inquiry
                              • Protocols & troubleshooting
                              • Placing an order
                              • RabMAb products
                              • Biochemical product FAQs
                              • Training
                              • Browse by Target
                              Company
                              • Corporate site
                              • Investor relations
                              • Company news
                              • Careers
                              • About us
                              • Blog
                              Events
                              • Tradeshows
                              • Conferences
                              International websites
                              • abcam.cn
                              • abcam.co.jp

                              Join with us

                              • LinkedIn
                              • facebook
                              • Twitter
                              • YouTube
                              • Terms of sale
                              • Website terms of use
                              • Cookie policy
                              • Privacy policy
                              • Legal
                              • Modern slavery statement
                              © 1998-2023 Abcam plc. All rights reserved.